Preliminary results of Preserflo Microshunt versus Preserflo Microshunt and Ologen implantation

Author:

Vastardis IraklisORCID,Fili Sofia,Perdikakis Georgios,Kontopoulou Kalliopi,Balidis Miltos,Gatzioufas Zisis,Kohlhaas Markus

Abstract

Abstract Purpose To report preliminary 6-month results on the use of the Preserflo Microshunt implant with and without Ologen in 50 pseudophakic eyes with moderate to advanced primary open-angle glaucoma (POAG). Methods Fifty pseudophakic eyes underwent ab externo Preserflo Microshunt implantation. Data was gathered retrospectively and two groups were then created, group A with application of MMC 0.2 mg/ml and group B with MMC 0.2 mg/ml and Ologen collagen matrix (OCM) implantation. Absolute success was regarded as the percentage of eyes achieving: a) 5 ≤ intraocular pressure (IOP) ≤ 13 mmHg, b) 5 ≤ IOP ≤ 16 mmHg, and c) 5 ≤ IOP ≤ 21 mmHg without additional medication or surgery and qualified success was regarded as the percentage of eyes achieving a) IOP ≤ 13 mmHg, b) IOP ≤ 16 mmHg, and c) IOP ≤ 21 mmHg with or without medication. Evaluation was performed using a log-rank Kaplan-Meier test. A scatterplot analysis presented the treatment effect data of all eyes with a minimum of 20% IOP reduction per case. Failure was defined as requiring additional surgery, IOP greater than 21 mmHg with or without medication and failure to reach 20% IOP reduction. Results Mean postoperative IOP was significantly lower in both groups. IOP decreased by 49.06% in group A and by 53.01% in group B at 6 months (P < 0.88), respectively. Medication use was lower in both groups (Wilcoxon test, P < 0.001). The absolute and qualified success rates were not statistically significant between the groups (all P > 0.05). Cumulative IOP results per case were not statistically different in group A compared with group B. One revision surgery in group A (4% failure rate) and three in group B (12% failure rate) were performed. Conclusions Both groups showed equal results in terms of cumulative and mean IOP reduction, medication reduction as well as in absolute and qualified success rates. No significant difference was found in any parameters tested between Preserflo Microshunt with MMC 0.2 mg/ml and with or without OCM implantation at 6 months. Long-term follow-up is required to further evaluate this data.

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3