Altering chromatic aberration: how this latest trend in intraocular-lens design affects visual quality in pseudophakic patients

Author:

Łabuz Grzegorz,Güngör Helin,Auffarth Gerd U.ORCID,Yildirim Timur M.,Khoramnia Ramin

Abstract

Abstract Background Chromatic aberration of the eye results from the dispersion of polychromatic light at the interfaces of ocular media. An intraocular lens (IOL) based approach utilizing the diffractive-multifocal principle has been proposed for its correction, but the clinical evidence on the impact of reducing or increasing chromatic aberration on the visual quality of pseudophakic patients remains scarce. Methods In this cross-sectional study, longitudinal chromatic aberration (LCA) effects were studied monocularly in 37 patients implanted with a monofocal lens. LogMAR corrected distance visual acuity (VA) and defocus curve at the + 1.0 D to − 2.0 D range were assessed. Contrast sensitivity (CS) was evaluated at far and at four spatial frequencies. Measurements were performed with the eye's natural conditions, as well as with increased and corrected (by the same amount) LCA, which was altered by introducing zero-power trial triplets. Results The mean (± standard deviation) logMAR VA was − 0.11 ± 0.07 for the natural condition, − 0.13 ± 0.07 for the LCA-corrected eye, and − 0.06 ± 0.08 for the eye with increased LCA. A sharp decline of the defocus tolerance was found after the LCA correction with the VA value of 0.38 ± 0.15 logMAR at − 1.5 D. However, for the natural and increased LCA, it was 0.32 ± 0.16 logMAR and 0.25 ± 0.13 logMAR, respectively. CS was improved at all spatial frequencies after the LCA correction, which was closely followed by the natural-eye performance. Increased LCA resulted in reduced CS, mainly at higher spatial frequencies. Conclusions We demonstrated that elevating chromatic aberration above the natural level of monofocal patients extends their depth of focus while causing a measurable albeit minimal reduction in visual function. Still, the observed changes indicate that neither correction nor increase of LCA yields a substantial clinical effect on distance VA and CS in monofocal pseudophakia.

Funder

Klaus Tschira Stiftung

Universitätsklinikum Heidelberg

Publisher

Springer Science and Business Media LLC

Subject

Ophthalmology,Health Professions (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3