Background
Whole-body magnetic resonance imaging (WB-MRI) has shown its accuracy in the diagnosis of skeletal metastases in patients with known primary solid cancers. The standard protocol was a combination of T1 and short tau inversion recovery (STIR) sequences. Herein, this study was conducted to elucidate the role of the T2-Dixon sequence as a rapid alternative to the standard protocol with the assessment of its diagnostic accuracy and comparability to the established methodology.
Methods
This prospective study included 30 patients with primary solid malignancies who underwent WB-MRI. The sequences obtained were T1WI, STIR, and T2-Dixon (fat-only and water-only images). Skeletal metastases were evaluated in each sequence. Results were compared between the T1-STIR combination and T2-Dixon fat and water reconstructions.
Results
The sensitivity of fat and water reconstructions from a single T2-Dixon in the detection of lytic skeletal metastases was marginally superior to a combination of T1WI and STIR sequences (0–7%). Detection of mixed lesions demonstrated equally high sensitivity in both protocols. Sclerotic metastases detection in WB-MRI showed low sensitivity in both protocols. However, specificity surpassed 95% for all lesion types in both protocols. Overall image quality was favored (in 87–90% of patients) in T2-Dixon images. The overall estimated acquisition timing using T2-Dixon appeared to be approximately half that of the standard T1-STIR combination.
Conclusions
WB-MRI using T2-Dixon fat and water reconstructions showed similar accuracy to T1WI and STIR combination in the evaluation of skeletal metastases in patients with primary solid cancers with significantly shorter acquisition time.
Publisher
Springer Science and Business Media LLC
Reference20 articles.
1. Dresen RC, De Vuysere S, De Keyzer F, Van Cutsem E, Prenen H, Vanslembrouck R, De Hertogh G, Wolthuis A, D’Hoore A, Vandecaveye V (2019) Whole-body diffusion-weighted MRI for operability assessment in patients with colorectal cancer and peritoneal metastases. Cancer Imaging 19(1):1–10. https://doi.org/10.1186/s40644-018-0187-z
2. Takahara T, Imai Y, Yamashita T, Yasuda S, Nasu S, Van Cauteren M (2004) Diffusion weighted whole body imaging with background body signal suppression (DWIBS): technical improvement using free breathing, STIR and high resolution 3D display. Radiat Med 22(4):275–282
3. Walker R, Kessar P, Blanchard R, Dimasi M, Harper K, DeCarvalho V, Yucel EK, Patriquin L, Eustace S (2000) Turbo stir magnetic resonance imaging as a whole-body screening tool for metastases in patients with breast carcinoma: preliminary clinical experience. J Magn Reson Imaging 11(4):343–350. https://doi.org/10.1002/(SICI)1522-2586(200004)11:4%3c343::AID-JMRI1%3e3.0.CO;2-P
4. Kwee TC, Kwee RM, Verdonck LF, Bierings MB, Nievelstein RA (2008) Magnetic resonance imaging for the detection of bone marrow involvement in malignant lymphoma. Br J Haematol 141(1):60–68. https://doi.org/10.1111/j.1365-2141.2008.07020.x
5. Ghanem N, Lohrmann C, Engelhardt M, Pache G, Uhl M, Saueressig U, Kotter E, Langer M (2006) Whole-body MRI in the detection of bone marrow infiltration in patients with plasma cell neoplasms in comparison to the radiological Skeletal Survey. Clin Imaging 30(6):440–441. https://doi.org/10.1016/j.clinimag.2006.08.018