Utility of gated SPECT parameters in detection of coronary artery disease in patients with normal perfusion images

Author:

Chantadisai MaythineeORCID,Sirisalipoch SasitornORCID,Vachatimanont SiraORCID

Abstract

Abstract Background False negative myocardial perfusion images on single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) is a substantial problem in the interpretation of MPI. To explore possible parameters from gated SPECT that could detected coronary artery disease (CAD) in patients with normal perfusion images, we retrospectively selected patients who underwent a 2-day Tc-99 m MIBI adenosine stress/rest MPI and a subsequent invasive coronary angiography. Gated SPECT parameters, including end systolic volume (ESV), end diastolic volume (EDV), left ventricular ejection fraction (LVEF), and transient ischemic dilation (TID) ratio of patients with and without CAD were compared and assessed for their respective diagnostic performance using receiver operating characteristics (ROC) area under the curve (AUC). Results Among 22 patients with normal perfusion images, 7 patients had CAD. Despite the small number of patients, we found significant differences between the ESV, the EDV, and the LVEF between patients with and without CAD. The analysis of ROC curve showed the stress ESV could excellently detect CAD (AUC = 0.900). The rest ESV, the stress EDV, the rest EDV, the stress LVEF and the rest LVEF could likewise perform well in the detection of CAD (AUC = 0.833, 0.819, 0.790, 0.862, and 0.838, respectively). In contrast, the change in LVEF and the TID ratio (AUC = 0.667 and 0.524, respectively) did not seem as reliable as other parameters. Optimal cutoffs for detection of CAD in patients with normal perfusion images from our study were ≥ 20.0 mL for the stress ESV, ≥ 71.0 mL for the stress EDV, ≤ 66.3 EF units for the stress LVEF, ≥ 18.0 mL for the rest ESV, ≥ 67.0 mL for the rest EDV and ≤ 70.0 EF unit for the rest LVEF. Conclusions Gated SPECT parameters could facilitate detection of CAD in patient with normal perfusion images on Tc-99m MIBI MPI. These parameters should be carefully interpreted to improve diagnostic accuracy and reduce false negative MPI.

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3