Exploratory study to assess feasibility of intracerebral hemorrhage detection by point of care cranial ultrasound

Author:

Sarwal Aarti,Patel YashORCID,D’Agostino Ralph,Brown Patrick,Wolfe Stacey Q.,Bushnell Cheryl,Glass Casey,Duncan Pamela

Abstract

Abstract Background Limited studies have evaluated the use of ultrasound for detection of intracerebral hemorrhage (ICH) using diagnostic ultrasound Transcranial Doppler machines in adults. The feasibility of ICH detection using Point of care Ultrasound (POCUS) machines has not been explored. We evaluated the feasibility of using cranial POCUS B mode imaging performed using intensive care unit (ICU) POCUS device for ICH detection with a secondary goal of mapping optimal imaging technique and brain topography likely to affect sensitivity and specificity of ICH detection with POCUS. Materials and methods After obtaining IRB approval, a blinded investigator performed cranial ultrasound (Fujifilm, Sonosite® Xporte, transcranial and abdominal presets) through temporal windows on 11 patients with intracerebral pathology within 72 h of last CT/MRI (computed tomography scan/magnetic resonance imaging) brain after being admitted to a neurocritical care unit in Aug 2020 and Nov 2020–Mar 2021. Images were then compared to patient’s CT/MRI to inform topography. Inferential statistics were reported. Results Mean age was 57 (28–77 years) and 6/11 were female. Six patients were diagnosed with ICH, 3 with ischemic stroke, 1 subarachnoid hemorrhage, and 1 brain tumor. The sensitivity and specificity of point of care diagnosis of ICH compared to CT/MRI brain was 100% and 50%, respectively. Mean time between ultrasound scan and CT/MRI was 13.3 h (21 min–39 h). Falx cerebri, choroid calcification and midbrain-related artifacts were the most reproducible hyperechoic signals. Abdominal preset on high gain yielded less artifact than Transcranial Doppler preset for cranial B mode imaging. False positive ICH diagnosis was attributed to intracerebral tumor and midbrain-related artifact. Conclusions Our exploratory analysis yielded preliminary data on use of point of care cranial ultrasound for ICH diagnosis to inform imaging techniques, cranial topography on B mode and sample size estimation for future studies to evaluate sensitivity and specificity of cranial POCUS in adult patients. This pilot study is limited by small sample size and over representation of ICH in the study. Cranial POCUS is feasible using POCUS machines and may have potential as a screening tool if validated in adequately powered studies.

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3