Clinical evaluation of percutaneous and intra-operative device closure of atrial septal defects under transesophageal echocardiographic guidance: one center experience and mid-term follow-up

Author:

Zhu Peng,Qiang Haifeng,Liu Fei,Xie Peng,Zheng Shaoyi,Sun YongORCID

Abstract

Abstract Objective The percutaneous closure of a single secundum atrial septal defect (ASD) under transesophageal echocardiography guidance as an accepted alternative to the transcatheter closure with fluoroscopy has been proven. However, the technique has not been routinely used. This study was to present and share our experience in comparing the clinical outcomes of the percutaneous and intra-operative device closure (IODC) of atrial septal defects without fluoroscopy. Methods From January 2013 to December 2016, 103 patients with maximum diameters of ASD of less than 30 mm were allocated to groups taking either the percutaneous closure of atrial septal defects approach (PASD group, n = 53) or the intra-operative device closure approach (IODC Group, n = 50). They were operated on using the minimally invasive Amplatzer duct occluder under the guidance of transesophageal echocardiography without cardiopulmonary bypass. Echocardiography was performed to obtain an en face view of the ASD and important surrounding structures before the operation. Patient characteristics, perioperative data, and follow-up data were retrospectively documented and analyzed. Results Patient characteristics were comparable between the two groups. These were no differences in the maximum diameters of defects and the size of the occluders in each group (16.4 ± 5.3 mm vs16.4 ± 5.2 mm, P = 0.98; 22.4 ± 5.8 mm vs 21.3 ± 6.6 mm, P = 0.38). Intracardiac manipulation time was 20.72 ± 7.70 min in the PASD group and 6.01 ± 1.03 min in the IODC group (P < 0.001). The procedure time was 28.70 ± 10.41 min in the PASD group and 39.13 ± 6.03 min in the IODC group (P < 0.001). The successful closure defect was 100% in both groups when the maximum diameter of defect less than 25 mm. Four patients the PASD groups with maximum diameters between 25 mm and 30 mm were transferred to the IOCD group after unsuccessful device implantations. The total occlusion rate was 82% immediately after deployment, 98% at 3 months, and 100% at 6 months. No cardiac-related complications occurred during the follow-up period of between 3 to 65 months (mean 21.4 ± 9.8 months). Conclusions Percutaneous device closures of Secundum atrial septal defects showed safety and high efficiency in patients under guidance by transesophageal echocardiography when compared with intra-operative device closures and are especially suited for women and children.

Funder

Fundación para el Fomento en Asturias de la Investigación Científica Aplicada y la Tecnología

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3