Author:
Hiremath C. S.,Jain Anil R.,Garg Anurag,Gupta Nirmal,Mishra Yugal K.,Meharwal Zile Singh,Thakur Nityanand,Maslekar Atul A.,Shastri Naman
Abstract
Abstract
Background
Bioprosthesis has been increasingly implanted for the treatment of transvalvular disease across the world. A new Dafodil™ pericardial bioprosthesis (Meril Life Sciences Pvt. Ltd., India) recently approved by Conformité Européenne (CE) is a tri-leaflet, stented, bovine valve. The purpose of Dafodil-1 first-in-human trial was to evaluate clinical safety and performance (including hemodynamic parameters) of the Dafodil pericardial bioprosthesis in patients who underwent aortic or mitral valve replacement.
Methods
This prospective, multicenter clinical trial enrolled 60 patients (Aortic: 30 patients; Mitral: 30 patients) from seven sites across India. Safety endpoints were early (≤30 days) and late (> 30 days) mortality and valve-related morbidity. The performance endpoints were hemodynamic performance, improvement in NYHA functional class, and change in the quality of life using SF-12v1 health survey.
Results
From July 2017 to July 2018, 60 patients underwent implantation of the Dafodil pericardial bioprosthesis. Post-operatively, NYHA functional class significantly improved in all the patients (Aortic: 90% NYHA class-I and 10% NYHA class-II; Mitral: 96.55% NYHA class-I and 3.45% NYHA class-II; P < 0.001). There was no death in aortic valve replacement patients till 12-month. In mitral valve replacement patients, early mortalities occurred in three patients, and late mortality occurred in one patient; none of these were valve-related. Freedom from all-cause mortality reported was 93.33% at 12-month. Mean aortic pressure gradient decreased from 52.71 ± 24.47 mmHg [with 0.89 ± 0.70 cm2 effective orifice area (EOA)] pre-operatively to 14.49 ± 6.58 mmHg (EOA: 1.85 ± 0.27 cm2) at 12-month. Overall, the mitral mean pressure gradient and EOA were 4.41 ± 1.69 mmHg and 2.67 ± 0.48 cm2, respectively, at 12-month. Significant improvement (P < 0.05) in the patients’ quality of life was reported at all follow-ups.
Conclusions
The clinical safety and performance of the Dafodil pericardial bioprosthesis were favourable at 12-month. Moreover, a study with a larger patient population and longer follow-up is warranted to further assess the device.
Trial registration
Dafodil-1 trial has been prospectively registered on 10/07/2017 under Clinical Trial Registry-India (http://www.ctri.nic.in). (Registration number: CTRI/2017/07/009008).
Funder
Meril Life Sciences Pvt. Ltd., India
Publisher
Springer Science and Business Media LLC
Subject
Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine
Reference31 articles.
1. Gürsoy MO, Kalçık M, Yesin M, Karakoyun S, Bayam E, Gündüz S, et al. A global perspective on mechanical prosthetic heart valve thrombosis: diagnostic and therapeutic challenges. Anatolian J Cardiol. 2016;16:980–9.
2. Hosain N, Amin F, Rehman S, Koirala B. Know thy neighbors: the status of cardiac surgery in the south Asian countries around India. Indian Heart J. 2017;69:790–6.
3. Mannam G, Mishra Y, Modi R, Gokhale AGK, Sethuratnam R, Pandey K, et al. Early hemodynamic performance of the trifecta surgical bioprosthesis aortic valve in Indian patient population: 12 month outcomes of the EVEREST post-market study. J Cardiothorac Surg. 2018;13:96.
4. Rahimtoola SH. Choice of prosthetic heart valve for adult patients. J Am Coll Cardiol. 2003;41:893–904.
5. Myken PS, Bech-Hansen O. A 20-year experience of 1712 patients with the Biocor porcine bioprosthesis. J Thorac Cardiovasc Surg. 2009;137:76–81.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献