Incidence, microbiological and immunological characteristics of ventilator-associated pneumonia assessed by bronchoalveolar lavage and endotracheal aspirate in a prospective cohort of COVID-19 patients: CoV-AP study

Author:

Mangioni Davide,Panigada Mauro,Palomba Emanuele,Bobbio Chiara,Chatenoud Liliane,Alagna Laura,Fumagalli Jacopo,Gori Andrea,Grancini Anna,Guzzardella Amedeo,Lombardi Andrea,Matinato Caterina,Meli Andrea,Muscatello Antonio,Porretti Laura,Tomasello Mara,Trombetta Elena,Valenti Luca,Bandera Alessandra,Grasselli Giacomo

Abstract

Abstract Background No univocal recommendation exists for microbiological diagnosis of ventilator-associated pneumonia (VAP). Sampling of either proximal or distal respiratory tract likely impacts on the broad range of VAP incidence between cohorts. Immune biomarkers to rule-in/rule-out VAP diagnosis, although promising, have not yet been validated. COVID-19-induced ARDS made VAP recognition even more challenging, often leading to overdiagnosis and overtreatment. We evaluated the impact of different respiratory samples and laboratory techniques on VAP incidence and microbiological findings in COVID-19 patients. Methods Prospective single-centre cohort study conducted among COVID-19 mechanically ventilated patients in Policlinico Hospital (Milan, Italy) from January 2021 to May 2022. Microbiological confirmation of suspected VAP (sVAP) was based on concomitant endotracheal aspirates (ETA) and bronchoalveolar lavage (BAL). Conventional and fast microbiology (FILMARRAY® Pneumonia Panel plus, BALFAPPP) as well as immunological markers (immune cells and inflammatory cytokines) was analysed. Results Seventy-nine patients were included. Exposure to antibiotics and steroid therapy before ICU admission occurred in 51/79 (64.6%) and 60/79 (65.9%) patients, respectively. Median duration of MV at VAP suspicion was 6 (5–9) days. Incidence rate of microbiologically confirmed VAP was 33.1 (95% CI 22.1–44.0) and 20.1 (95% CI 12.5–27.7) according to ETA and BAL, respectively. Concordance between ETA and BAL was observed in 35/49 (71.4%) cases, concordance between BALFAPPP and BAL in 39/49 (79.6%) cases. With BAL as reference standard, ETA showed 88.9% (95% CI 70.8–97.7) sensitivity and 50.0% (95% CI 28.2–71.8) specificity (Cohen’s Kappa 0.40, 95% CI 0.16–0.65). BALFAPPP showed 95.0% (95% CI 75.1–99.9) sensitivity and 69% (95% CI 49.2–84.7) specificity (Cohen’s Kappa 0.60, 95% CI 0.39–0.81). BAL IL-1β differed significantly between VAP (135 (IQR 11–450) pg/ml) and no-VAP (10 (IQR 2.9–105) pg/ml) patients (P = 0.03). Conclusions In COVID-19 ICU patients, differences in microbial sampling at VAP suspicion could lead to high variability in VAP incidence and microbiological findings. Concordance between ETA and BAL was mainly limited by over 20% of ETA positive and BAL negative samples, while BALFAPPP showed high sensitivity but limited specificity when evaluating in-panel targets only. These factors should be considered when comparing results of cohorts with different sampling. BAL IL-1β showed potential in discriminating microbiologically confirmed VAP. Clinical Trial registration: NCT04766983, registered on February 23, 2021.

Publisher

Springer Science and Business Media LLC

Subject

Critical Care and Intensive Care Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3