Author:
Fukano Kentaro,Iizuka Yusuke,Nishiyama Seiya,Yoshinaga Koichi,Uchino Shigehiko,Sasabuchi Yusuke,Sanui Masamitsu
Abstract
Abstract
Background
It has been 50 years since the pulmonary artery catheter was introduced, but the actual use of pulmonary artery catheters in recent years is unknown. Some randomized controlled trials have reported no causality with mortality, but some observational studies have been published showing an association with mortality for patients with cardiogenic shock, and the association with a pulmonary artery catheter and mortality is unknown. The aim of this study was to investigate the utilization of pulmonary artery catheters (PACs) in the intensive care unit (ICU) and to examine their association with mortality, taking into account differences between hospitals.
Methods
This is a retrospective analysis using the Japanese Intensive care PAtient Database, a multicenter, prospective, observational registry in Japanese ICUs. We included patients aged 16 years or older who were admitted to the ICU for reasons other than procedures. We excluded patients who were discharged within 24 h or had missing values. We compared the prognosis of patients with and without PAC. The primary outcome was hospital mortality. We performed propensity score analysis to adjust for baseline characteristics and hospital characteristics.
Results
Among 184,705 patients in this registry from April 2015 to December 2020, 59,922 patients were included in the analysis. Most patients (94.0%) with a PAC in place had cardiovascular disease. There was a wide variation in the frequency of PAC use between hospitals, from 0 to 60.3% (median 14.4%, interquartile range 2.2–28.6%). Hospital mortality was not significantly different between the PAC use group and the non-PAC use group in patients after adjustment for propensity score analysis (3.9% vs 4.3%; difference, − 0.4%; 95% CI − 1.1 to 0.3; p = 0.32). Among patients with cardiac disease, those with post-open-heart surgery and those in shock, hospital mortality was also not significantly different between the two groups (3.4% vs 3.7%, p = 0.45, 1.7% vs 1.7%, p = 0.93, 4.8% vs 4.9%, p = 0.87).
Conclusions
The frequency of PAC use varied among hospitals. PAC use for ICU patients was not associated with lower hospital mortality after adjusting for differences between hospitals.
Publisher
Springer Science and Business Media LLC
Subject
Critical Care and Intensive Care Medicine
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献