Evaluation of lung perfusion by using lung perfusion SPECT and lung CT with breathing synchronization software

Author:

Hashimoto HidenobuORCID,Soma Tsutomu,Mizumura Sunao,Kokubo Tadashi,Nakanishi Rine,Ikeda Takanori

Abstract

Abstract Background Lung perfusion using 99mTc-macroaggregated albumin single-photon emission computed tomography (SPECT) and lung computed tomography (CT) is a useful modality for identifying patients with pulmonary artery embolism. However, conformity between SPECT and CT at the bottom of the lung is generally low. This study aims to investigate the progression of conformity between lung perfusion SPECT and lung CT using a breathing synchronization software. Methods Among 95 consecutive patients who underwent lung perfusion SPECT and lung CT within 14 days because of suspected pulmonary embolism between June 2019 and August 2020 in department of cardiovascular medicine, we identified 28 patients (73 ± 10 years) who had normal pulmonary artery on contrast lung CT. We compared lung volumes calculated using lung perfusion SPECT and lung CT as gold standard. Visual conformity between lung SPECT and lung CT was scored 0–4 (0: 0–25%, 1: 25–50%, 2: 50–75%, 3: 75–90%, 4: > 90%) by two specialists in nuclear medicine and assessed. Results The lung volume calculated from lung CT was 3749 ± 788 ml. The lung volume calculated from lung perfusion SPECT without using the breathing synchronization software was 3091 ± 610 ml. There was a significant difference between the lung volume calculated from CT and SPECT without using the breathing synchronization software (P < 0.01). The lung volume calculated from lung perfusion SPECT using the breathing synchronization software was 3435 ± 686 ml, and there was no significant difference between the lung volume calculated from CT and SPECT using the breathing synchronization software. The visual score improved with the use of breathing synchronization software (without software; 1.9 ± 0.6 vs. with software; 3.4 ± 0.7, P < 0.001). Conclusion This study demonstrated that the breathing synchronization software could improve conformity between lung perfusion SPECT and lung CT.

Funder

Japan Society for the Promotion of Science

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Molecular Medicine,Biophysics,Computer Science (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3