Effects of muscle-to-electrode distance on the human diaphragm electromyogram

Author:

Beck J.1,Sinderby C.1,Weinberg J.1,Grassino A.1

Affiliation:

1. Meakins-Christie Laboratories, McGill University, Montreal, Canada.

Abstract

It has been suggested that esophageal recordings of the diaphragm electromyogram (EMGdi) are influenced by changes in chest wall configuration. Whether the changes are of physiological or artifactual origin is unclear. For example, the distance between the esophageal electrode and the diaphragm is likely to alter with chest wall configuration and may lead to misinterpretations of EMGdi. The aims of this study were 1) to evaluate and quantify the effect of the muscle-to-electrode (ME) distance filter on EMGdi, as obtained with a multiple-array esophageal electrode, 2) to take advantage of the ME distance filter to locate the position of the diaphragm with respect to the electrode, and 3) to evaluate the influence of lung volume and chest wall configuration on EMGdi center frequency (CF) while controlling for the ME distance filter and signal quality. Five subjects performed six static contractions of the diaphragm at each of seven chest wall configurations, as evaluated by the method of K. Konno and J. Mead (J. Appl. Physiol. 22: 407–422, 1967). EMGdi was measured with seven pairs of electrodes mounted on an esophageal catheter. The pair of electrodes whose EMGdi power spectra were the least filtered by the ME distance was assumed to be closest to the diaphragm. The results of the study indicated that 1) EMGdi power spectra were strongly affected by the distance between the diaphragm and the electrodes. CF decreased by approximately 1 Hz/mm displacement away from the electrode pair closest to the diaphragm; and 2) no systematic relationship was found between changes in chest wall configuration and CF, when CF was measured from the electrode pair closest to the diaphragm. We conclude that the EMGdi CF can be reliably measured with a multiple-array esophageal electrode that covers the span of diaphragmatic excursion and by selecting the pair of electrodes that is the closest to the diaphragm.

Publisher

American Physiological Society

Subject

Physiology (medical),Physiology

Cited by 60 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3