Affiliation:
1. NeuroMuscular Research Center, Boston University, Massachusetts02215.
Abstract
1. Synchronization of concurrently active motor-unit firings was studied in six human muscles performing isometric constant-force contractions at 30% of the maximal level. The myoelectric signal was detected with a quadrifilar needle electrode and was decomposed into its constituent motor-unit action-potential trains with the Precision Decomposition technique, whose accuracy has been proven previously. 2. Synchronization was considered as the tendency of two motor units to fire at fixed time intervals with respect to each other more often than would be expected if the motor units fired independently. A rigorous statistical technique was used to measure the presence of peaks in the cross-interval histogram of pairs of motor-unit action-potential trains. The location of the center of peak as well as their width and amplitude were measured. A synch index was developed to measure the percentage of firings that were synchronized. The percentage of concurrently active motor-unit pairs that contained synchronized firings was measured. 3. Synchronization of motor-unit firings was observed to occur in two modalities. The short-term modality was seen as a peak in the cross-interval histogram centered about zero-time delay (0.5 +/- 2.9 ms, mean +/- SD) and with an average width of 4.5 +/- 2.5 ms. The long-term modality was seen as a peak centered at latencies ranging from 8 to 76 ms. On the average, the peaks of the long-term synchronization were 36% lower but had approximately the same width as the peaks for the short-term synchronization. Short-term synchronization was seen in 60% of the motor-unit paris, whereas long-term synchronization was seen in 10% of the pairs. 4. Short-term synchronization occurred in bursts of consecutive firings, ranging in number from 1 to 10, with 91% of all synchronized firing occurring in groups of 1 or 2; and the bursts of discharges appeared at sporadic times during the contraction. 5. The amount of synchronization in motor-unit pairs was found to be low. In the six muscles that were tested, an average of 8.0% of all the firings were short-term synchronized, and an average of 1.0% were long-term synchronized. The synch index was statistically indistinguishable (P = 0.07-0.89) among the different muscles and among 9 of the 11 subjects tested. 6. Sixty percent of concurrently active motor-unit pairs displayed short-term synchronization, 10% of the pairs displayed long-term synchronization, and 8% displayed both modalities.(ABSTRACT TRUNCATED AT 400 WORDS)
Publisher
American Physiological Society
Subject
Physiology,General Neuroscience
Cited by
120 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献