Magnetic resonance diagnostic criteria of non-compaction cardiomyopathy: new diagnostic criteria still needed?

Author:

Gaižauskienė Karolina1,Glembockytė Gabrielė2,Glaveckaitė Sigita3,Valevičienė Nomeda Rima1

Affiliation:

1. Department of Radiology, Nuclear Medicine and Medical Physics, Institute of Biomedical Sciences , Vilnius University Faculty of Medicine , Vilnius , Lithuania ; Radiology and Nuclear Medicine Centre, Vilnius University Hospital Santaros Klinikos, Vilnius, Lithuania

2. Faculty of Medicine , Vilnius University , Vilnius , Lithuania

3. Clinic of Cardiac and Vascular Diseases, Institute of Clinical Medicine , Vilnius University Faculty of Medicine , Vilnius , Lithuania ; Centre for Cardiology and Angiology , Vilnius University Hospital Santaros Klinikos , Vilnius , Lithuania

Abstract

Summary Non-compaction cardiomyopathy (NCC) is a rare pathology, but the exact rates of its prevalence are not known due to the lack of a diagnostic gold standard. The purpose of this article is to analyse the available cardiovascular magnetic resonance (CMR) diagnostic criteria of non-compaction described in the literature and to compare their sensitivity and specificity in the diagnosis of NCC. A search of available literature related to the CMR diagnostic criteria of myocardial non-compaction was conducted in the medical database PubMed in February of 2022. The period of publication of scientific articles covered the years from 1996 to 2022. A total of 7 full-text scientific articles were included in the final literature review. The main diagnostic criteria were used: the maximum non-compact (NCM) to compact myocardial layers (CM) ratio (NCM:CM), the percentage of trabeculated left ventricular (LV) myocardial mass, the percentage of trabeculated LV myocardial volume, the non-compact myocardial mass index of the total LV, and the determination of the total LV and the maximal fractal dimension (FD) of the apex with the use of fractal analysis. The lack of accurate diagnostic criteria results in an overdiagnosis of NCC. The highest sensitivity and specificity are associated with the maximum FD > 1.30 of the apex established by applying the fractal analysis method. Fractal analysis requires dedicated software, and this method is difficult to apply in routine clinical practice. Thus, the diagnostic criteria for the NCC using magnetic resonance imaging with higher diagnostic value remain to be sought.

Publisher

Walter de Gruyter GmbH

Subject

General Economics, Econometrics and Finance

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3