Assessment of resection margins during breast-conserving surgery using multimodal optical coherence tomography

Author:

Vorontsov D. A.1ORCID,Gubarkova E. V.2ORCID,Sirotkina M. A.2ORCID,Sovetskiy A. A.3ORCID,Aleksakhina S. N.4ORCID,Tabagua T. T.4ORCID,Busko E. A.4ORCID,Imyanitov E. N.4ORCID,Kuznetsov S. S.1ORCID,Vorontsov A. Yu.1ORCID,Zagaynova E. V.2ORCID,Gamayunov S. V.1ORCID,Zaytsev V. Yu.3ORCID,Krivorotko P. V.4ORCID,Gladkova N. D.2ORCID

Affiliation:

1. Nizhny Novgorod Regional Oncologic Hospital

2. Privolzhsky Research Medical University, Ministry of Health of Russia

3. Federal Research Center A.V. Gaponov-Grekhov Institute of Applied Physics of the Russian Academy of Sciences

4. N.N. Petrov National Medical Research Center of Oncology, Ministry of Health of Russia

Abstract

Background. Breast cancer (BC) has been ranked first in morbidity and mortality among the female population in Russian Federation for several years. Rapid and accurate intraoperative examination of the cleanliness of resection margins is the main condition for breast-conserving surgery (BCS) to reduce the risks of local recurrence.Aim. To examine the tumor margins and assess the cleanliness of the resection margins in BCS in patients diagnosed with BC using multimodal optical coherence tomography (MM OCT) with comparative planned histological and additional molecular genetic analysis.Materials and methods. The study was carried out on postoperative samples of tumor and non-tumor breast tissue obtained from 115 patients with BC T1–2N0M0G2–3 stage IA–IIA, after BCS in the volume of radical resection or lumpectomy with histological control of the resection margins. A spectral domain MM OCT device (OCT 1300-E, BioMedTech LLC, Russia) was used, which provides structural OCT images to study the backscattering properties of tissue and allows performing a quantitative assessment of the elastic properties of the tissue by compression optical coherence elastography (OCE).Results. The MM OCT method was able to determine the exact margins between the tumor and non-tumor breast tissue. The main signs of the tumor were a decrease in the level and depth of penetration of the OCT signal in the structural OCT images, as well as an increase in the stiffness values (>200 kPa) in the OCE images with the highest stiffness values (>600 kPa) in the area of tumor cell accumulations. The use of compression OCE made it possible to detect clusters of tumor cells in the margins of resection at a distance of 5 mm from the visible border of the tumor. Among the 132 studied resection margins in 6 cases, the positive resection margin was determined by the OCE method, which was subsequently confirmed histologically. The negative resection margins were characterized by the lowest stiffness values (<200 kPa) in the OCE images and were confirmed by both histological analysis and molecular genetic analysis. ROC-analysis established a threshold stiffness value of 159.8 kPa, which indicates the presence of tumor tissue at the resection margins in the presence of a high stiffness area larger than 500 µm. The high diagnostic accuracy of the OCE method (98.5 %) was determined to distinguish between the negative and positive resection margins during BCS.Conclusion. The use of MM OCT with OCE modality makes it possible to clearly distinguish different types of breast tissue in BC (adipose tissue, connective tissue, accumulation of tumor cells). MM OCT can be used as an additional intraoperative tool for visualizing tumor cells boundaries and assessing the cleanliness of resection margins in real time during BCS.

Publisher

Publishing House ABV Press

Subject

Pharmacology (medical),Obstetrics and Gynecology,Radiology, Nuclear Medicine and imaging,Oncology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3