Comparison of trifocal toric and bifocal toric intraocular lens implantation in patients with cataract and high corneal astigmatism

Author:

Gencer Merve Bozkurt, ,Yasar Erdogan,Onal Ozkan, ,

Abstract

AIM: To investigate and compare the quality of life, satisfaction, contrast sensitivity, glare, depth perception, and intraocular lens (IOL) rotation in patients who underwent trifocal toric and bifocal toric IOLs. METHODS: A total of 80 eyes of 40 patients were included in this prospective study. Twenty patients in each group were implanted with trifocal toric and bifocal toric IOL, respectively. Preoperative and postoperative 6-month measurements were recorded for both patient groups. Comprehensive anterior and posterior segment examinations, distance-intermediate-near visual acuity values and the visual function scale questionnaire results were evaluated at these examinations. Patient satisfaction, contrast sensitivity, glare, intermediate-near and distance stereopsis and IOL rotation were also evaluated. RESULTS: No significant difference was found between the groups in terms of distance and near visual acuities (P=0.269, P=0.451). Intermediate visual acuity was significantly increased in the trifocal toric group (P<0.001). The visual function scale results were increased after surgery in both groups (P=0.001 and P<0.001), with no difference determined between them (P=0.158 and P=0.691). The number of patients wearing glasses was low in both groups and there was no significant difference between the groups (P>0.05). The overall satisfaction in the trifocal toric group was significantly higher than in the bifocal toric group (P=0.03). The highest sensitivity was observed at 6 cpd spatial frequency in all patients under photopic conditions (1.80±0.24 logU, 1.74±0.20 logU). Distance-intermediate-near binocular depth perception results in both groups were higher in the trifocal toric group (P=0.02, 0.048, 0.003, respectively). Although there was no significant difference for 3 meters stereopsis, the trifocal toric group had higher depth perception (P=0.577). Mean rotation was 5.76°±3.93° in the trifocal toric group and 12°±7.1° in the bifocal toric group. CONCLUSION: Better results in the middle distance are obtained in the trifocal toric group and less IOL rotation due to digital system-coordinated surgery. Moreover, the overall satisfaction in the trifocal toric group is significantly higher than in the bifocal toric group.

Publisher

Press of International Journal of Ophthalmology (IJO Press)

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3