Location of the Optic Foramen Relative to the Sphenoid Sinus and Orbital Apex Structures

Author:

Cinaroglu Selim,Zor Kursad Ramazan,Guresci Kursat,Keles Hacı

Abstract

Background: Orbital decompression is performed to reduce intraorbital pressure by removing the fat tissue and bone around the orbit. Access to proper equipment, experienced personnel, and adequate anatomical knowledge are essential to perform this procedure. To achieve maximum decompression, surgeons need to open the orbit up to the apex, including the optic foramen and the annulus of Zinn. Objectives: This study aimed to determine the location of the sphenoid sinus relative to the optic foramen using computed tomography (CT) scan, which is essential for orbital decompression surgery, in the Central Anatolia Region, Turkey. Patients and Methods: This cross-sectional study was conducted on 64 patients from the Turkish population between March 15 and April 15, 2021 in the Central Anatolia Region. The patients were selected using the purposive sampling method. Based on the cranial CT scans, a total of 128 orbits were evaluated using the hospital’s picture archiving and communication system. Patients included in this study were admitted to the hospital with headache. However, their CT images, evaluated by an experienced radiologist, were reported to be normal. The relationship between the optic foramen and the anterior surface of the sphenoid sinus was examined, and the location of the optic foramen was determined as anterior, posterior, or equal to the sphenoid sinus. Descriptive statistics were measured for statistical analysis. Results: The participants of this study included 32 men and 32 women in the age range of 20 - 67 years. Based on the analyses, the optic foramen was mainly opposite to the anterior aspect of the sphenoid sinus in both females and males; this finding was more prominent in females. In the right orbit, the mean distance of the optic foramen to the anterior surface of the sphenoid sinus was +6.97 mm if the optic foramen was anterior to the anterior surface of the sphenoid sinus, while it was -4.1 mm if the optic foramen was located posteriorly to the anterior surface of the sphenoid sinus. Similarly, in the left orbit, the mean distance of the optic foramen to the anterior surface of the sphenoid sinus was +6.97 mm if the optic foramen was located anteriorly, while it was -4.15 mm if the optic foramen was located posteriorly to the anterior surface of the sphenoid sinus. The position of the optic foramen was symmetrical in 60.9% of cases in the two orbits. Conclusion: Based on the results of CT scan, the optic foramen was mainly located opposite to the anterior aspect of the sphenoid sinus; this finding was more frequently observed in females (59.4%) than in males (40.6%). The present results can provide further information for surgeons to perform orbital decompression or surgeries posterior to the orbit.

Publisher

Briefland

Subject

Radiology, Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Optic foramen location on computed tomography;Archives of Craniofacial Surgery;2023-08-20

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3