Normal Values of Distal Radioulnar Joint Kinematics during a Dynamic Press Test

Author:

Thillemann Janni Kjærgaard123ORCID,De Raedt Sepp34,Petersen Emil Toft123,Puhakka Katriina Bøcker56,Hansen Torben Bæk12,Stilling Maiken237

Affiliation:

1. Department of Orthopaedics, University Clinic for Hand, Hip and Knee Surgery, Hospital Unit West, Holstebro, Denmark

2. Department of Clinical Medicine, Aarhus University, Aarhus N, Denmark

3. AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus N, Denmark

4. NRT X-RAY A/S, Hasselager, Denmark

5. Department of Radiology, Aarhus University Hospital, Aarhus N, Denmark

6. Department of Radiology, Regional Hospital Horsens, Horsens, Denmark

7. Department of Orthopaedic Surgery, Aarhus University, Aarhus N, Denmark

Abstract

Abstract Background Measurement of in vivo distal radioulnar joint (DRUJ) pathomechanics during simple activities can represent the disability experienced by patients and may be useful in diagnostics of DRUJ instability. A first step is to describe the physiological normal limits for DRUJ kinematics in a reproducible and precise test setup, which was the aim of this study. Methods DRUJ kinematics were evaluated in 33 participants with dynamic radiostereometry (RSA) while performing a standardized press test examination. AutoRSA software was used for image analyses. Computed tomography (CT) forearm bone models were generated, and standardized anatomical axes were applied to estimate kinematic outcomes including, DRUJ translation, DRUJ position ratio, and changes in ulnar variance. Repeatability of dynamic RSA press test double examinations was evaluated to estimate the precision and intraclass correlation coefficient (ICC) test–retest agreement. Results The maximum force during the press test was 6.0 kg (95% confidence interval [CI]: 5.1–6.9), which resulted in 4.7 mm (95% CI: 4.2–5.1) DRUJ translation, DRUJ position ratio of 0.40 (95% CI: 0.33–0.44), and increase in ulnar variance of 1.1 mm (95% CI: 1.0–1.2). The mean maximum DRUJ translation leveled off after a 5 kg force application. The DRUJ translation ICC coefficient was 0.93 within a prediction interval of ± 0.53mm. Conclusions This clinical study demonstrates the normal values of DRUJ kinematics and reports excellent agreement and high precision of the press tests examination using an automated noninvasive dynamic RSA imaging method based on patient-specific CT bone models. The next step is the application of the method in patients with arthroscopic verified triangular fibrocartilage complex injuries. Level of Evidence This is a Level IV, case series study.

Funder

The Danish Rheumatism Association and Innovation Fund Denmark

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3