Technical Aspects of High-Resolution Color-Coded Duplex Sonography for the Design of Perforator Flaps

Author:

Kehrer Andreas1ORCID,Heidekrueger Paul I.1,Lonic Daniel1,Klein Silvan1,Anker Alexandra1,Taeger Christian D.1,Biermann Niklas1,Jung Ernst Michael2,Prantl Lukas1,da Silva Natascha Platz Batista2

Affiliation:

1. Department of Plastic and Reconstructive Surgery, University Medical Center Regensburg, Regensburg, Germany

2. Department of Radiology, Ultrasound Center, University Medical Center Regensburg, Regensburg, Germany

Abstract

Abstract Background Technical aspects are of utmost significance for an efficient execution in designing perforator flaps with high-resolution color-coded Duplex sonography (CCDS). The following study evaluates decisive factors for a successful microvessel examination conducted by the microsurgeon. Methods Technical knowledge presented in this study was based on a series of more than 200 perforator flaps planned with CCDS. Flap reconstructions were performed at the University Hospital Regensburg, Germany, from July 2013 to January 2021. Standard high-resolution ultrasound (US) devices with linear multifrequency transducers of 4 to 18 MHz were used. Modes and device settings were evaluated regarding applicability by microsurgeons. Key steps for safe perforator identification and further optional steps for additional assessment should be discriminated. Results Different US modes including brightness mode (B-mode), color flow (CF), power Doppler (PD), pulse wave (PW), and blood flow (B-Flow) were used. Transducers from 15 MHz and up were favorable to detect microvessels. Knobology of a standard US device regarding buttons, switches, and specific onscreen options with relevance for perforator mapping was subcategorized in four different groups. For qualitative and quantitative evaluation of microvessels, different US modes were tested with respect to their usefulness.Vital elements of the CCDS exam are disaggregated into three key steps for safe perforator identification and three optional steps for further perforator characterization. A standardized protocol for the CCDS exams was applied. Downregulation of pulse-repetition frequency/scale to adapt device sensitivity to slow-flow velocities represented the most important criterion to visualize microvessels.Qualitative microvessel evaluation was performed in B-mode, CCDS, PD mode, and B-Flow mode. Quantitative assessment was executed using PW-mode and CCDS measuring the microvessels' diameter (mm) and flow characteristics. Quantitative information may be obtained using PW-mode and the distance-measuring tool in CF-mode. Conclusion Technical aspects with respect to proper device trimming and application decisively impact CCDS-guided perforator vessel identification and evaluation.

Publisher

Georg Thieme Verlag KG

Subject

Surgery

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3