To Study Acute Changes in Brain Oxygenation on MRI in Healthcare Workers Using N95 Mask and PPE Kits for Six Hours a Day

Author:

Vakharia Rahul Jitendra1ORCID,Jani Ishaan1ORCID,Yadav Shashibala1,Kurian Thomas2

Affiliation:

1. Department of Radiodiagnosis, Wockhardt Hospital, Mumbai, Maharashtra, India

2. MRI Applications, Philips India Limited, Mumbai, Maharashtra, India

Abstract

Abstract Background Due to long working hours wearing an N95 mask and PPE kit during the COVID-19 pandemic, the healthcare workers (HCWs) complained of headaches, confusion, and exhaustion. This study was therefore performed to study the changes in brain oxygenation. Aim To compare brain oxygenation in health care workers wearing an N95 mask with a PPE kit versus a three-ply mask during an intensive care setting for 6 hours. Materials and Methods Thirty clinicians and 30 paramedical staff participated in the study. The control (three-ply mask) and subject (N95 mask with PPE) groups included 15 clinicians and 15 paramedical staff. A comparative analysis of brain oxygenation using a 3T magnetic resonance imaging (MRI) machine was performed in these two groups at the beginning and the end of their work shift. Results The mean age of the individuals in the control and subject groups was 30.8 and 30.13 years, respectively. The median value of brain oxygenation in the control and subject groups in the pre-shift was between 33 and 31 and post-shift was 30 and 24. The drop in brain oxygenation in subjects was more than the controls (p = 0.004) in the post-shift assessments. The cerebral blood flow (CBF) in the bilateral middle cerebral artery (MCA) using arterial spin labeling (ASL) showed a rise in CBF in both groups post-shift as compared with the pre-shift values. The median values of the right and left MCA in the control and subject groups pre-shift were 82.75/83.45 and 89.75/106.65. The post-shift median values of both MCAs of the control and subject groups were 115.65/115.55 and 109.60/119.49. Conclusion MRI-BOLD imaging revealed a significant drop in brain oxygenation in the subject group as compared with the control group. Multiphasic-ASL showed a compensatory rise in CBF in both groups.

Publisher

Georg Thieme Verlag KG

Subject

Radiology, Nuclear Medicine and imaging

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3