Intramuscular Near-Infrared Spectroscopy for Muscle Flap Monitoring in a Porcine Model

Author:

Bai Wubin1,Guo Hexia23,Ouyang Wei2,Weng Yang2,Wu Changsheng2,Liu Yihan1,Zang Hao2,Jacobson Lauren4,Xu Yameng5,Lu Di2,Hu Ziying2,Li Shuo2,Arafa Hany M.2,Yang Quansan26,Westman Amanda M.4,MacEwan Matthew R.7,Rogers John A.23689,Pet Mitchell A.4ORCID

Affiliation:

1. Department of Applied Physical Sciences, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina

2. Department of Materials Science and Engineering, Querrey Simpson Institute for Bioelectronics, Northwestern University, Chicago, Illinois

3. Department of Materials Science and Engineering, Northwestern University, Evanston, Illinois

4. Division of Plastic and Reconstructive Surgery, Department of Surgery, School of Medicine, Washington University, St. Louis, Missouri

5. Department of Mechanical Engineering and Materials Science, Washington University, St. Louis, Missouri

6. Department of Mechanical Engineering, Northwestern University, Evanston, Illinois

7. Department of Neurosurgery, School of Medicine, Washington University, St. Louis, Missouri

8. Department of Biomedical Engineering, Northwestern University, Evanston, Illinois

9. Department of Neurological Surgery, Feinberg School of Medicine, Northwestern University, Chicago, Illinois

Abstract

Abstract Background Current near-infrared spectroscopy (NIRS)-based systems for continuous flap monitoring are limited to flaps which carry a cutaneous paddle. As such, this useful and reliable technology has not previously been applicable to muscle-only free flaps where other modalities with substantial limitations continue to be utilized. Methods We present the first NIRS probe which allows continuous monitoring of local tissue oxygen saturation (StO2) directly within the substance of muscle tissue. This probe is flexible, subcentimeter in scale, waterproof, biocompatible, and is fitted with resorbable barbs which facilitate temporary autostabilization followed by easy atraumatic removal. This novel device was compared with a ViOptix T.Ox monitor in a porcine rectus abdominus myocutaneous flap model of arterial and venous occlusions. During these experiments, the T.Ox device was affixed to the skin paddle, while the novel probe was within the muscle component of the same flap. Results The intramuscular NIRS device and skin-mounted ViOptix T.Ox devices produced very similar StO2 tracings throughout the vascular clamping events, with obvious and parallel changes occurring upon vascular clamping and release. The normalized cross-correlation at zero lag describing correspondence between the novel intramuscular NIRS and T.Ox devices was >0.99. Conclusion This novel intramuscular NIRS probe offers continuous monitoring of oxygen saturation within muscle flaps. This experiment demonstrates the potential suitability of this intramuscular NIRS probe for the task of muscle-only free flap monitoring, where NIRS has not previously been applicable. Testing in the clinical environment is necessary to assess durability and reliability.

Publisher

Georg Thieme Verlag KG

Subject

Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3