Comparison between Two-Dimensional and Three-Dimensional Assessments of the Fetal Corpus Callosum: Reproducibility of Measurements and Acquisition Time

Author:

Baert Jonathan1,Pomar Léo12,Mchirgui Ali2,Lambert Véronique2,Carles Gabriel2,Hcini Najeh2,Baud David1ORCID,Vial Yvan1

Affiliation:

1. Department of “Woman-Mother-Child,” Ultrasound and Fetal Medicine Unit, Lausanne University Hospital, University of Lausanne, Lausanne, Switzerland

2. Department of Obstetrics and Gynaecology, Centre Hospitalier de l'Ouest Guyanais Franck Joly, Saint-Laurent-du-Maroni, France

Abstract

AbstractThe objective of this article was to study the reproducibility and reliability of the fetal corpus callosum measurements between two-dimensional (2D) and three-dimensional (3D) acquisitions. This prospective study enrolled 475 fetuses, monitored between 18 and 38 weeks of gestation by two operators. Starting from a transcerebellar axial plane, 3D and 2D mid-sagittal views of the corpus callosum were obtained. Measurements of length and thickness were performed and underwent quality control by independent reviewers. The acquisition time of the two methods was measured. Means, differences, and linear correlations were analyzed using t-test, regression and Pearson's correlation coefficients, and Bland–Altman's plots. This analysis was performed for each operator to test the interobserver reproducibility. Among the 432 cases measured using both methods, 380 (88%) were validated by quality control. The mean corpus callosum length and thickness were essentially the same using 2D and 3D measurements (2D: 33.8 ± 8.7 vs. 3D: 33.7 ± 8.7 mm, 2D: 2.2 ± 0.4 vs. 3D: 2.2 ± 0.4 mm, respectively; mean ± standard deviation [SD]). Linear regression coefficients and Pearson's coefficients were similar for length (2D: 0.8283 and 0.9191 vs. 3D: 0.8271 and 0.9095), but slightly different regarding thickness (2D: 0.6775 and 0.8231 vs. 3D: 0.5831 and 0.7636). Differences between 2D and 3D measurements, considering Bland–Altman's plots and correlated with gestational age, were acceptable (2D: 0.097 ± 0.559 mm, 3D: 0.004 ± 0.111 mm). The acquisition time required was significantly lower for 3D acquisitions (3D: 25.2 ± 14.5 seconds vs. 2D: 35.1 ± 19.4 seconds, p < 0.01). Linear regression and Pearson's coefficients for the measurements of corpus callosum length and thickness using 2D or 3D acquisitions did not differ between the operators. This study confirmed good reproducibility of corpus callosum assessment by transabdominal 3D acquisitions. The good feasibility in routine scans may lead to better screening for callosal dysgenesis.

Publisher

Georg Thieme Verlag KG

Subject

Neurology (clinical),Pediatrics, Perinatology and Child Health

Reference23 articles.

1. Atlas-based segmentation of developing tissues in the human brain with quantitative validation in young fetuses;P A Habas;Hum Brain Mapp,2010

2. Imaging the fetal brain in the second and third trimesters using transvaginal sonography;A Monteagudo;Obstet Gynecol,1991

3. Biometry of the fetal corpus callosum by three-dimensional ultrasound;S Pashaj;Ultrasound Obstet Gynecol,2013

4. Distinguishing 3 classes of corpus callosal abnormalities in consanguineous families;R M Hanna;Neurology,2011

5. Antenatal diagnosis of agenesis of the corpus callosum;I Craven;Clin Radiol,2015

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3