What is the Best Multimodality Combination for Intraoperative Spinal Cord Monitoring of Motor Function? A Multicenter Study by the Monitoring Committee of the Japanese Society for Spine Surgery and Related Research

Author:

Ito Zenya1,Matsuyama Yukihiro2,Ando Muneharu3,Kawabata Shigenori4,Kanchiku Tsukasa5,Kida Kazunobu6,Fujiwara Yasushi7,Yamada Kei8,Yamamoto Naoya9,Kobayashi Sho2,Saito Takanori10,Wada Kanichiro11,Satomi Kazuhiko12,Shinomiya Kenichi13,Tani Toshikazu6

Affiliation:

1. Nagoya University, Nagoya, Aichi Prefecture, Japan

2. Hamamatsu Medical University, Hamamatsu, Shizuoka, Japan

3. Wakayama Rosai Hospital, Wakayama, Japan

4. Tokyo Medical and Dental University, Tokyo, Japan

5. Yamaguchi University, Yamaguchi, Japan

6. Kubokawa Hospital, Shimanto, Kochi, Japan

7. Asa Citizens Hospital, Hiroshima, Japan

8. Kurume University, Kurume, Japan

9. Tokyo Women's Medical University, Tokyo, Japan

10. Kansai Medical University, Moriguchi, Osaka, Japan

11. Hirosaki University, Hirosaki, Aomori, Japan

12. Kugayama Hospital, Tokyo, Japan

13. Yokohama City Minato Red Cross Hospital, Yokohama, Kanagawa, Japan

Abstract

Study Design Surgeon survey. Objective To analyze multimodal intraoperative monitoring (MIOM) for different combinations of methods based on the collected data and determine the best combination. Methods A questionnaire was sent to 72 training institutions to analyze and compile data about monitoring that had been conducted during the preceding 5 years to obtain data on the following: (1) types of monitoring; (2) names and number of diseases; (3) conditions of anesthesia; (4) condition of stimulation, the monitored muscle and its number; (5) complications; and (6) preoperative and postoperative manual muscle testing, presence of dysesthesia, and the duration of postoperative motor deficit. Sensitivity and specificity, false-positive rates, and false-negative rates were examined for each type of monitoring, along with the relationship between each type of monitoring and the period of postoperative motor deficit. Results Comparison of the various combinations showed transcranial electrical stimulation motor evoked potential (TcMEP) + cord evoked potential after stimulation to the brain (Br-SCEP) combination had the highest sensitivity (90%). The TcMEP + somatosensory evoked potential (SSEP) and TcMEP + spinal cord evoked potential after stimulation to the spinal cord (Sp-SCEP) combinations each had a sensitivity of 80%, exhibiting little difference between their sensitivity and that obtained when TcMEP alone was used. Meanwhile, the sensitivity was as low as 50% with Br-SCEP + Sp-SCEP (i.e., the cases where TcMEP was not included). Conclusions The best multimodality combination for intraoperative spinal cord monitoring is TcMEP + Br-SCEP, which had the highest sensitivity (90%), the lowest false-positive rate (6.1%), and the lowest false-negative rate (0.2%).

Publisher

SAGE Publications

Subject

Clinical Neurology,Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3