Contact Lens Fitting in Patients with Keratoconus – A Retrospective Assessment of 200 Patients

Author:

Richter Kathrin1,Jullien Theresia1,Klühspies Ulrike1,Langenbucher Achim2ORCID,Seitz Berthold1ORCID,Eppig Timo2ORCID

Affiliation:

1. Klinik für Augenheilkunde, Universitätsklinikum des Saarlandes und Medizinische Fakultät der Universität des Saarlandes, Homburg/Saar

2. Institut für Experimentelle Ophthalmologie, Universität des Saarlandes, Homburg/Saar

Abstract

Abstract Background and Purpose Nowadays, keratoconus (KC) is very well treatable in a stage-oriented manner. A wide range of designs and materials of contact lenses (CL) are available for the treatment of KC. The aim of this study was to evaluate the possibilities, the possible challenges and the visual outcome of lens fitting in KC eyes. Patients and Methods This retrospective study includes data from 200 patients who received a lens fitting trial in our contact lens service between 2006 and 2016. We documented ophthalmological parameters, the type of prescribed CL, the number of required trial lenses and possible causes of the failure of the lens fitting. Results The mean age at initial lens fitting was 33.9 ± 12.5 years. In 98.8% of the cases, the fitting was performed with rigid gas permeable lenses, in 90.1% with four-curve lenses. Of the total number of aspheric lenses prescribed, 87.5% were fitted in keratoconus stages “1” to “2” (topographic keratoconus classification; Oculus Keratograph). Back surface toric lenses or bitoric lenses were fitted to 61.7% in keratoconus stages “2 – 3” to “4”. Before patients received their final CL, a median of 2 trial lenses were required (max. 16). Mean visual acuity with lens correction was 0.8 ± 0.2 at the initial fitting, mean visual acuity with glasses correction was 0.5 ± 0.3. In 7.7% of the eyes, the KC lens fitting was discontinued due to the advanced stage of keratoconus, requiring a corneal transplant. Reasons for discontinuing contact lens fitting included lens intolerance (2.3%), application problems (0.3%) or acute corneal hydrops (0.3%). Discontinuation of lens wearing due to incompatibilities or application problems occurred in only four cases (1.1%) in the further course after lens fitting. Conclusions The use of contact lenses is an integral part of the stage-appropriate therapy of keratoconus. Good visual acuity can be achieved in all stages of keratoconus with a low drop-out rate. In most cases, the adjustment is carried out with rigid gas permeable lenses with a four-curve geometry. In initial stages, aspherical lenses may be sufficient. Toric lenses can be fitted in advanced stages when rotationally symmetrical lenses cannot achieve a satisfactory fit. If contact lenses have been successfully fitted, there are only a few cases in which patients abandon their contact lenses because of intolerance.

Publisher

Georg Thieme Verlag KG

Subject

Ophthalmology

Reference28 articles.

1. Keratoconus;Y S Rabinowitz;Surv Ophthalmol,1998

2. Keratokonusprogression im Seitenvergleich;S Goebels;Klin Monbl Augenheilkd,2017

3. Keratokonuslinse. Das kleine Korrektionswunder;U Klühspies;Ophthalmologe,2013

4. Contact lens management of keratoconus;L E Downie;Clin Exp Optom,2015

5. Kontaktlinsenanpassung

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3