A Preclinical Model to Study the Influence of Graft Force on the Healing of the Anterior Cruciate Ligament Graft

Author:

Ma Richard1,Stasiak Mark2,Deng Xiang-Hua2,Rodeo Scott2

Affiliation:

1. Department of Orthopaedic Surgery, Missouri Orthopaedic Institute, Thompson Laboratory for Regenerative Orthopaedics, University of Missouri, Columbia, Missouri

2. Sports Medicine and Shoulder Service, Tissue Engineering, Regeneration, and Repair Program, Hospital for Special Surgery, New York

Abstract

AbstractThe purpose of this study is to establish a small animal anterior cruciate ligament (ACL) reconstruction research model where ACL graft force can be varied to create different graft force patterns with controlled knee motion. Cadaveric (n = 10) and in vivo (n = 10) rat knees underwent ACL resection followed by reconstruction using a soft tissue autograft. Five cadaveric and five in vivo knees received a nonisometric, high-force femoral graft tunnel position. Five cadaveric and five in vivo knees received a more isometric, low-force graft tunnel position. ACL graft force (N) was then recorded as the knee was ranged from extension to 90 degrees using a custom knee flexion device. Our results demonstrate that distinct ACL graft force patterns were generated for the high-force and low-force femoral graft tunnels. For high-force ACL grafts, ACL graft forces increased as the knee was flexed both in cadaveric and in vivo knees. At 90 degrees of knee flexion, high-force ACL grafts had significantly greater mean graft force when compared with baseline (cadaver: 7.76 ± 0.54 N at 90 degrees vs. 4.94 ± 0.14 N at 0 degree, p = 0.004; in vivo: 7.29 ± 0.42 N at 90 degrees vs. 4.74 ± 0.13 N at 0 degree, p = 0.007). In contrast, the graft forces for low-force ACL grafts did not change with knee flexion (cadaver: 4.94 ± 0.11 N at 90 degrees vs. 4.72 ± 0.14 N at 0 degree, p = 0.41; in vivo: 4.78 ± 0.26 N at 90 degrees vs. 4.77 ± 0.06 N at 0 degree, p = 1). Compared with nonisometric ACL grafts, the graft force for grafts placed in an isometric position had significantly lower ACL graft forces at 15, 30, 45, 60, 70, and 90 degrees in both cadaveric and in vivo knees. In conclusion, we have developed a novel ACL reconstruction model that can reproducibly produce two ACL graft force patterns. This model would permit further research on how ACL graft forces may affect subsequent graft healing, maturation, and function.

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3