Spray coagulation with snare-tip versus argon plasma coagulation: An ex vivo study evaluating tissue effects

Author:

Fetz Andrew1,Farnell David2,Irani Shayan3,Gan S. Ian1

Affiliation:

1. Gastroenterology Department, Vancouver General Hospital, University of British Columbia, Vancouver, BC, Canada

2. Pathology Department, Vancouver General Hospital, University of British Columbia, Vancouver, BC, Canada

3. Digestive Disease Institute, Virginia Mason Medical Center, Seattle, Washington, United States

Abstract

Abstract Background and study aims Argon plasma coagulation (APC) is an effective and safe modality for many gastrointestinal conditions requiring hemostasis and/or ablation. However, it can be quite costly. A potentially more cost-effective alternative is snare-tip spray coagulation (SC). This study aimed to determine whether SC would be a safe and effective alternative to APC using an ex-vivo model. Methods Using two resected porcine stomach, 36 randomized gastric areas were ablated for 2 seconds with either APC at 1.0 L/min 20 W (APC20) and 1.4 L/min 40 W (APC40) or SC with Effect 2 60 W (SC60) and 80 W (SC80) from 3 mm. Extent of tissue injury was then analyzed histopathologically. Results The mean coagulation depth was 790 ± 159 µm and 825 ± 467 µm for SC60 (n = 9) and SC80 (n = 8), respectively. This was compared to 539 ± 151 µm for APC20 (n = 8) and 779 ± 267 µm for APC40 (n = 9). Mean difference (MD) in coagulation depth between SC60 and APC40 was 12 µm (95 % confidence interval [CI], –191 to 214 µm; P = 0.91) and was 47 µm (95 %CI, –162 to 255 µm; P = 0.81) between SC80 and APC40. There was a greater depth of injury with APC40 (MD, 240 µm; 95 %CI, 62 to 418 µm; P = 0.04) and with SC60 (MD, 252 µm; 95 %CI, 141 to 362 µm; P = 0.004) when compared to APC20. Mean cross-sectional area of coagulation was 2.39 ± 0.852 mm² for SC60 and 2.54 ± 1.83 mm² for SC80 compared to 1.22 ± 0.569 mm² for APC20 and 1.99 ± 0.769 mm² for APC40. Seventy-eight percent reached the muscularis mucosa (MM) and 11 % the submucosa in the SC60 group compared to 50 % and 38 % in SC80 and 56 % and 11 % in APC40, respectively. Thirty-eight percent of APC20 specimens reached the MM. The muscularis propria was unaffected. Conclusions This small ex-vivo study suggests that SC60 and SC80 may be safe alternatives to APC40 with comparable coagulation depths and area effects.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology,Medicine (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3