Development and validation of an automated algorithm to evaluate the abundance of bubbles in small bowel capsule endoscopy

Author:

Pietri Olivia1,Rezgui Gada2,Histace Aymeric2,Camus Marine13,Nion-Larmurier Isabelle1,Li Cynthia14,Becq Aymeric1,Abou Ali Einas1,Romain Olivier2,Chaput Ulriikka1,Marteau Philippe12,Florent Christian12,Dray Xavier123

Affiliation:

1. APHP Saint Antoine Hospital, Department of Hepatogastroenterology, Paris, France

2. ETIS, ENSEA, Cergy-Pontoise University, Cergy-Pontoise, France

3. Sorbonne University, Paris, France

4. College of Arts and Sciences, Drexel University, Philadelphia, Pennsylvania, United States

Abstract

Abstract Background and study aims Bubbles can impair visualization of the small bowel (SB) mucosa during capsule endoscopy (CE). We aimed to develop and validate a computed algorithm that would allow evaluation of the abundance of bubbles in SB-CE still frames. Patients and methods Two sets of 200 SB-CE normal still frames were created. Two experienced SB-CE readers analyzed both sets of images twice, in a random order. Each still frame was categorized as presenting with < 10 % or ≥ 10 % of bubbles. Reproducibility (κ), sensitivity (Se), specificity (Sp), receiver operating characteristic curve, and calculation time were measured for different algorithms (Grey-level of co-occurrence matrix [GLCM], fractal dimension, Hough transform, and speeded-up robust features [SURF]) using the experts’ analysis as reference. Algorithms with highest reproducibility, Se and Sp were then selected for a validation step on the second set of frames. Criteria for validation were κ = 1, Se ≥ 90 %, Sp ≥ 85 %, and a calculation time < 1 second. Results Both SURF and GLCM algorithms had high operating points (Se and Sp over 90 %) and a perfect reproducibility (κ = 1). The validation step showed the GLCM detector strategy had the best diagnostic performances, with a Se of 95.79 %, a Sp of 95.19 %, and a calculation time of 0.037 seconds per frame. Conclusion A computed algorithm based on a GLCM detector strategy had high diagnostic performance allowing assessment of the abundance of bubbles in SB-CE still frames. This algorithm could be of interest for clinical use (quality reporting) and for research purposes (objective comparison tool of different preparations).

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology,Medicine (miscellaneous)

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3