Evaluation of the Quality of Canal Obturation Using the Continuous Wave Method after Shaping with Different NiTi Rotary Instruments by Micro-CT

Author:

Junior Adirson Jorge1,Gelio Mariana Bena1,Galvani Lucas David1ORCID,Monteiro Jardel Camilo do Carmo1,Zaniboni Joissi Ferrari1,Neto Paulo Fermino da Costa1,Almeida Bernardo Mattos1,Kuga Milton Carlos1

Affiliation:

1. Department of Restorative Dentistry, Araraquara School of Dentistry, University of São Paulo State, UNESP, Araraquara, São Paulo, Brazil

Abstract

Abstract Objective The aim of this article was to evaluate the influence of mesial root canal preparation of mandibular molars with the reciprocal systems (RCP) and self-adjusting file (SAF) in the incidence of voids spaces in endodontic obturation performed by modified continuous wave compaction (MCWC) technique, through images obtained in micro-computed tomography (micro-CT). Materials and Methods Mesial roots of 15 mandibular molars, with two independent root canals, were divided into three groups (n = 5/roots), according to the endodontic instrumentation strategy (RCP, SAF, and twisted file [TWF]). After the root canals (n = 10, for each instrumentation system) were filled with MCWC, images of each specimen were obtained by micro-CT followed by three-dimensional reconstruction. The percentage of voids was obtained (in mm3) in relation of the total volume, cervical–middle, and apical thirds. Statistical Analysis The data obtained were submitted to statistical analysis by Kruskal–Wallis and Dunn tests (p < 0.05). Results With respect to the total volume of root canal, TWF demonstrated a lower percentage in comparison to SAF (p < 0.05). No significant difference was obtained between TWF and RCP or RCP and SAF (p > 0.05). In the apical third, RCP showed a smaller percentage of voids when compared with SAF (p < 0.05); however, TWF demonstrated similarity with RCP and SAF (p > 0.05). The middle–cervical third exhibited no statistically difference between TWF and RCP or RCP and SAF (p > 0.05), whereas TWF was lower than SAF (p < 0.05). Conclusion Root canal preparation of mesial root of mandibular molars with TWF provides a lower incidence of voids in the endodontic filling performed by MCWC.

Publisher

Georg Thieme Verlag KG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3