Variable Performance of D-dimer Testing by Hemostasis Laboratories: The Australasian/Asia-Pacific Experience

Author:

Favaloro Emmanuel J.123ORCID,Arunachalam Sandya4,Dean Elysse4

Affiliation:

1. Department of Haematology, Sydney Centres for Thrombosis and Haemostasis, Institute of Clinical Pathology and Medical Research (ICPMR), NSW Health Pathology, Westmead Hospital, Westmead, NSW, Australia

2. Faculty of Science and Health, Charles Sturt University, Wagga Wagga, NSW, Australia

3. School of Medical Sciences, Faculty of Medicine and Health, University of Sydney, Westmead Hospital, Westmead, New South Wales, Australia

4. RCPAQAP Haematology, St Leonards, NSW, Australia

Abstract

AbstractD-dimers represent the breakdown products of fibrin. Thus, elevated plasma D-dimers will arise following a thrombotic event, such as a deep vein thrombosis or a pulmonary embolism, and therefore, a nonelevated D-dimer is used to effectively exclude such events. D-dimers are also elevated in a range of other conditions, for example, during disseminated intravascular coagulation. D-dimer levels may also be associated with prognostic value. For example, highly raised D-dimer levels can be associated with worsening clinical features in coronavirus disease 2019. Thus, D-dimer testing represents a commonly requested hemostasis test, often performed in 24/7 laboratories. Unfortunately, D-dimer testing is neither standardized nor harmonized across manufacturers or laboratories. Indeed, considering reporting units and the magnitude of units, up to 28 different combinations may be reported by laboratories. We provide updated findings for D-dimer testing in our geographic region, using recent data from the Royal College of Pathologists of Australasia Quality Assurance Programs, an international external quality assessment program, currently with over 450 participants in the D-dimer module. Data show a wide variety of assays in use and variable outcomes in reported numerical values when assessing proficiency samples. D-dimer testing mostly comprised reagents from three main manufacturing suppliers, with a small number of users of reagents from other manufacturers. Reported results showed important differences in numerical values for the same homogeneous tested samples when normalized to a single reporting unit (e.g., mg/L). Nevertheless, despite using different test reagents and reporting, most participants uniformly identified D-dimer values as below or above a “detection” cut-off for samples that were constructed to be below or above most cut-off values. As expected, mixed findings were reported for samples containing levels around expected cut-off values. We hope that our findings, reflecting on the heterogeneity of test reagents and test data, help improve diagnostic testing for D-dimer testing and facilitate harmonization and standardization, in the future.

Publisher

Georg Thieme Verlag KG

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3