The Role of Proximal Locking Fixation in Volar Distal Radius Fracture Fixation

Author:

Gossett Leland1,Vu Giap H.2,Reizner Wayne1,Gira Emma3,Qiu Bowen1,Awad Hani A.13,Ketonis Constantinos1

Affiliation:

1. Department of Orthopaedics, University of Rochester School of Medicine and Dentistry, Rochester, New York

2. Division of Plastic Surgery, Department of Surgery, University of Rochester School of Medicine and Dentistry, Rochester, New York

3. Department of Biomedical Engineering, University of Rochester School of Medicine and Dentistry, Rochester, New York

Abstract

Abstract Background Volar-locked plating has become a popular treatment option for unstable distal radius fractures. While using locking screws in the distal fragment increases the stability of the fixation, the biomechanical benefits of locking fixation in the proximal fragment have not been definitively established. Purposes This study evaluated the initial mechanical behavior of the volar plating construct with different locking screw configurations in the proximal fragment. Methods Sixteen Sawbones radius models were used. An unstable metaphyseal distal radius fracture was created and fixated with a volar-locked plate. Four different screw configurations in the proximal fragment were tested: all nonlocking screws, locking screw in the distal-most hole, locking screw in the proximal-most hole, and locking screws in both the proximal- and distal-most holes. Initial stiffness, displacement during harmonic loading, and load-to-failure were compared among the three groups. Results The initial stiffness, displacement during harmonic loading, and load-to-failure did not significantly differ among the four proximal screw configurations (p < 0.05). Failure occurred via toggling of the screws in the configuration with all nonlocking screws and through screw breakage or locking mechanism failure in the configurations with locking screws. Conclusions The use of locking screws in the proximal fragment did not significantly affect the initial stability of volar distal radius plating. However, failure modes differed between the nonlocking and locking configurations, consistent with known mechanical properties of locking fixation. Further mechanical studies in cadaveric models and clinical trials are warranted to determine the optimal screw configuration in volar distal radius plating. Level of Evidence To be determined. Biomechanical study on synthetic models.

Publisher

Georg Thieme Verlag KG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3