Abstract

AbstractInstability and dislocation can occur in up to one in four cases following revision total hip arthroplasty (THA), and optimal placement of components is critical in avoiding re-revision. Computer-assisted navigation can improve accuracy and precision of component placement in primary THA; however, its role in revision surgery is not defined. The purpose of our study was to evaluate the effect of computer-assisted navigation on component placement in revision THA. This study was a retrospective, multicenter cohort of 128 patients (69 imageless navigation, 59 conventional) who underwent revision THA between March 2017 and January 2019. An imageless computer navigation device was utilized in 69 of the 128 patients. Acetabular component placement and the proportion placed in a functional safe zone were compared between navigation-assisted and conventional THA groups. Mean anteversion increased significantly in both the navigation group (18.6 ± 8.5 degrees vs. 21.6 ± 7.8 degrees, p = 0.03) and the control group (19.4 ± 9.6 degrees vs. 21.2 ± 9.8 degrees, p = 0.03). Postoperatively, the proportion of acetabular components within the safe zone in the navigation group (inclination: 88%, anteversion: 84%) was mildly improved over the control group (83 and 69%, respectively). Variance in inclination improved significantly in both the control (50.6 vs. 112.4 degrees, p = 0.002) and navigation (46.2 vs. 141.1 degrees, p < 0.001) groups. Anteversion variance worsened in the control group (96.3 vs. 87.6 degrees, p = 0.36) but the navigation group showed improvement (61.2 vs. 72.7 degrees, p = 0.25). Postoperative variance was significantly better in the navigation group compared to the control group (p = 0.04). Utilizing imageless navigation in revision THAs results in more consistent placement of the acetabular component as compared to nonnavigated revision surgeries.

Publisher

Georg Thieme Verlag KG

Subject

General Earth and Planetary Sciences,General Environmental Science

Reference42 articles.

1. Prevalence of Total Hip and Knee Replacement in the United States;H M Kremers;J Bone Joint Surg Am,2015

2. Projected volume of primary total joint arthroplasty in the U.S., 2014 to 2030;M Sloan;J Bone Joint Surg Am,2018

3. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030;S Kurtz;J Bone Joint Surg Am,2007

4. Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002;S Kurtz;J Bone Joint Surg Am,2005

5. Comparative epidemiology of revision arthroplasty: failed THA poses greater clinical and economic burdens than failed TKA;K J Bozic;Clin Orthop Relat Res,2015