Routine Echocardiography is not Required in Neonates with Arterial Ischemic Stroke

Author:

Bhagat Indira1ORCID,Sarkar Rohan2,Bapuraj Jayapalli R.3,Sarkar Subrata4ORCID

Affiliation:

1. Division of Neonatal-Perinatal Medicine, Central Michigan University, Mount Pleasant, Michigan

2. Research Volunteer, Michigan State University, East Lansing, Michigan

3. Division of Neuroradiology, University of Michigan, Ann Arbor, Michigan

4. Division of Neonatal-Perinatal Medicine, University of Michigan, Ann Arbor, Michigan

Abstract

Objective Current guidelines suggest routine echocardiography (ECHO) in the acute phase to exclude a cardiac source for neonatal arterial ischemic stroke (NAIS). However, the commonly assumed embolic origin from a cardiac source for NAIS is challenged and the need for ECHO in NAIS remains questionable, especially during the era of standard fetal anomaly scanning. Our hypothesis is that any complex cardiac defects potentially causing NAIS would likely be detected during routine prenatal scans, thus possibly making routine postnatal ECHO redundant. This study aimed to determine the prevalence of significant cardiac risk factors and evaluate the necessity of routine postnatal ECHO in NAIS during the routine use of prenatal fetal sonography. Study Design Retrospective review of 54 infants diagnosed with NAIS via brain magnetic resonance imaging who underwent an ECHO evaluation during the acute period to exclude potential cardiac origins for NAIS. Results Postnatal ECHO revealed no intracardiac thrombus or vegetation, and only identified structural heart anomalies in three (5%) infants. Interestingly, these three cases had already been diagnosed with syndromic conditions or chromosomal malformations prenatally. In the remaining infants, postnatal ECHO was either normal or showed minor abnormalities unlikely to have contributed to the stroke. The detection rates of complex cardiac anomalies from prenatal scans and postnatal ECHO were statistically similar (p = 0.617). Conclusion The probability of ECHO to exclude cardiac sources for NAIS is so low that in the era of standard fetal anomaly scanning, routine postnatal ECHO may not be necessary for all NAIS infants, except when chromosomal malformations are detected. Key Points

Publisher

Georg Thieme Verlag KG

Subject

Obstetrics and Gynecology,Pediatrics, Perinatology and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3