Influence factors on registration of three-dimensional contrast-enhanced ultrasound fusion imaging in evaluating the ablative margin – A phantom study

Author:

Zheng Ruiying1,Ye Jieyi12,Zhang Xiaoer1,Zhou Xiaoyu1,Huang Tongyi1,Xu Ming1,Cong Longfei3,Xie Xiaoyan1,Huang Guangliang1

Affiliation:

1. Division of Interventional Ultrasound, Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou, China

2. Division of Interventional Ultrasound, Department of Medical Ultrasonics, Foshan First Municipal People’s Hospital (The Affiliated Foshan Hospital of Sun Yat-sen University), Foshan, Guangdong, China

3. Medical imaging System Division General manager Shenzhen Mindray Bio-medical Electronics. LTD, Shenzhen, China

Abstract

BACKGROUND: Registration of three-dimensional contrast-enhanced ultrasound fusion imaging (3DCEUS-FI) is time-consuming to obtain high success rate. OBJECTIVE: To investigate the influence factors on registration success rate of 3DCEUS-FI. METHODS: Water tank phantoms were made to obtain mimicked pre- and post- radiofrequency ablation three-dimensional contrast-enhanced ultrasound (3DCEUS) and CT images. Orthogonal trials were designed according to factors including size, depth, enhancement level of mimicked tumor, diameter and number of mimicked adjacent vessels. Mimicked pre- and post-RFA 3DCEUS images of 72 trials were fused to assess ablative margin (AM) by two radiologists. With CT images as standard, 3DCEUS-FI accuracy was considered as the consistency of AM evaluation. The inter-observer agreement and the influence factors on registration success rates were analyzed. RESULTS: The intraclass correlation coefficient (ICC) for the consistency of AM evaluation between CT and 3DCEUS-FI in x-axis, y-axis or z-axis was 0.840∼0.948 (P < 0.001). The ICC for inter-observer agreement was 0.840∼0.948 (P < 0.001). The success rates of registration within mimicked vessels with diameter of 2 mm were significantly lower than those with diameter of 3 mm and 4 mm. CONCLUSIONS: The mimicked AM measured by 3DCEUS-FI had high accuracy and inter-observer agreement. Diameter of the mimicked adjacent vessels was significantly related to success rate of registration.

Publisher

IOS Press

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine,Hematology,Physiology

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3