Evaluating the influence of 6MV and 10MV photon beams on cervical cancer volumetric-modulated arc therapy plans

Author:

He Dong-Cheng,Zhu Zhi-Jian,Zhang Xiao-Ye,Zhang Yan,Hong Jun,Shi Ting-Ting,Han Ji-Hua

Abstract

BACKGROUND: Cervical cancer is a common gynecological cancer among women worldwide. OBJECTIVE: To determine the effects of 6 MV and 10 MV volumetric-modulated arc therapy (VMAT) photon beams on the target volume (TV) planning and critical organs in cases of cervical cancer. METHODS: Fifty patients with carcinoma of the cervix who underwent radiotherapy were selected. The transverse diameter (T) of the cross section of the upper edge of the sacroiliac joint on computerized tomography (CT) images of the patients was measured, and the mean value was calculated as 34 cm. All patients were divided into two groups: Group A (T < 34 cm) and Group B (T > 34 cm). The VMAT plans were generated using 6 MV and 10 MV plans separately. The prescription dose was 47.5 Gy, and the daily dose was 1.9 Gy. RESULTS: In Group A, the planning target volume (PTV) dose assessment parameters of 6 MV and 10 MV plans and their homogeneity and conformity indices were not statistically significantly different. A significant difference was observed between the 6 MV and 10 MV plans for the PTV dose assessment parameters and the homogeneity index of the plans for Group B. The monitor units (MUs) of the 10 MV plans were lower than in the 6 MV plans in both Groups A and B, and the difference was statistically significant. The assessment parameter V40 Gy of both the rectum and bladder in the 6 MV plans was smaller than the corresponding parameter in the 10 MV plans in Group A; in Group B, the assessment parameter V50 Gy of the rectum in the 10 MV plans was smaller than in the 6 MV plans. CONCLUSION: When T < 34 cm, 6 MV energy is more suitable for the external irradiation of cervical cancer. When T > 34 cm, 10 MV energy is more suitable for cervical cancer radiotherapy. Therefore, 10 MV should be considered for patients with a large abdominal size.

Publisher

IOS Press

Subject

Health Informatics,Biomedical Engineering,Information Systems,Biomaterials,Bioengineering,Biophysics

Reference25 articles.

1. Global cancer statistics;Torre;2012. CA Cancer J Clin.,2015

2. Cancer Statistics;Siegel;2017. CA Cancer J Clin.,2017

3. Long-term survival and risk of second cancers after radiotherapy for cervical cancer;Ohno;Int J Radiat Oncol Biol Phys.,2007

4. Evaluation the effect of photon beam energies on organ at risk doses in three-dimensional conformal radiation therapy;Molazadeh;Res J Appl Sci Eng Technol.,2013

5. Comparative dosimetry in narrow high-energy photon beams;Westermark;Phys Med Biol.,2000

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3