Shear wave elastography using high-frequency linear probe for kidney transplant monitoring: A methodological study

Author:

Yang Daopeng12,Zhuang Bowen1,Zheng Yanling1,Xu Ming1,Lin Jinhua1,Zhang Xiaoer1,Wang Changxi2,Xie Xiaoyan1,Huang Gang2,Xie Xiaohua1,Wang Yan1

Affiliation:

1. Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China

2. Organ Transplant Center, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China

Abstract

OBJECTIVES: To investigate the influencing factors of the image quality of shear wave elastography (SWE) performed using a high-frequency probe and its reproducibility for renal allografts. METHODS: A total of 211 patients with transplanted kidneys who underwent SWE examination performed using high-frequency or low-frequency probes were recruited for the study. The reproducibility of inter- and intraobserver agreements were analysed by using the intraclass correlation coefficient (ICC). According to the colour filling of the area of interest and imaging noise when conducting SWE, the image quality was classified as three grades: “good”, “common”, and “poor”. A logistic regression was used to analyse the independent factors for SWE quality. RESULTS: In the comparative analysis, high frequency, transection measurement and middle pole were selected as the appropriate measurement methods. Regarding reproducibility, the ICCs) of the intra- and interobserver agreements were 0.85 and 0.77, respectively. Multivariate analysis indicated that only the skin allograft distance and kidney width were independent variables for SWE quality. In the subgroup analysis of the skin-allograft distance, the “good” and “common” rates of images decreased as the distance increased, but the CV (coefficients of variation) showed the opposite trend. The SWE quality of kidney width <5.4 cm was significantly better than that of kidney width ≥5.4 cm. CONCLUSIONS: High-frequency SWE can be used in the evaluation of transplanted kidneys due to its good repeatability and high successful measurement rate, but we should pay attention to the influence of the skin-allograft distance and kidney width on SWE quality.

Publisher

IOS Press

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine,Hematology,Physiology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3