Usability of the novel ankle training equipment with spring resistance-based plantar press exercises in the standing position: A focus on chronic stroke patients with hemiplegic gait

Author:

Heo Jin-Su1,Lee Hyung-Joo2,Ko Byung-Woo2,Yoon Hyun-Soo3,Bae Young-Hyeon4

Affiliation:

1. Department of Clinical Rehabilitation Research, National Rehabilitation Research Institute, Seoul, Korea

2. Department of Rehabilitation and Assistive Technology, National Rehabilitation Research Institute, Seoul, Korea

3. Daegu Gyeongbuk Institute of Science and Technology, Daegu, Korea

4. Department of Healthcare and Public Health Research, National Rehabilitation Research Institute, Seoul, Korea

Abstract

BACKGROUND: To improve gait disability in patients with chronic stroke, ankle muscle strengthening and calf muscle stretching exercises are required. However, currently available ankle training equipment limit ankle exercises based on the position. Recently developed ankle training equipment enables spring resistance-based plantar press exercises to be performed in the standing position with weight support. OBJECTIVE: To conduct a usability test of the ankle training equipment in the standing position by stroke patients with hemiplegic gait and verify its effects on ankle movements. METHODS: The ankle training equipment was applied to five patients with chronic stroke and hemiplegic gait. In the standing position, the patients performed forefoot and rearfoot press exercises in the affected side with a day’s interval at 20 repetitions maximum (RM). During the exercises, surface electromyography (sEMG) was used to measure the maximum voluntary isometric contraction (%MVIC) of the leg muscles. The System Usability Scale (SUS) was used to assess the ankle training equipment. Wilcoxon signed-rank test was used to evaluate the differences in muscle activity between the two exercises. RESULTS: Forefoot and rearfoot press exercises increased the %MVIC in the biceps femoris. Additionally, the tibialis anterior and medial gastrocnemius activity was significantly different between the two exercises. The SUS was 78.75% (SD 12.7). CONCLUSION: The usability test of the passive-control foot press trainer (PFPT) that with improvements in the structure and functions for convenience, it could be commercialized. PFPT could be an alternative to the ankle rehabilitation robot that necessitates a sitting position.

Publisher

IOS Press

Subject

Health Informatics,Biomedical Engineering,Information Systems,Biomaterials,Bioengineering,Biophysics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3