Interferon gamma release assays for Diagnostic Evaluation of Active tuberculosis (IDEA): test accuracy study and economic evaluation

Author:

Takwoingi Yemisi1,Whitworth Hilary23,Rees-Roberts Melanie24,Badhan Amarjit24,Partlett Christopher1,Green Nathan5678,Boakye Aime24,Lambie Heather2,Marongiu Luigi2,Jit Mark89,White Peter5678,Deeks Jonathan J1,Kon Onn Min2410,Lalvani Ajit24

Affiliation:

1. Institute of Applied Health Research, University of Birmingham, Birmingham, UK

2. Tuberculosis Research Centre, National Heart and Lung Institute, Imperial College London, London, UK

3. Department of Clinical Research, London School of Hygiene & Tropical Medicine, London, UK

4. National Institute for Health Research (NIHR) Health Protection Research Unit in Respiratory Infections, Imperial College London, London, UK

5. NIHR Health Protection Research Unit in Modelling Methodology, Imperial College London, London, UK

6. Medical Research Council (MRC) Centre for Outbreak Analysis and Modelling, Imperial College London, London, UK

7. Department of Infectious Disease Epidemiology, Imperial College London, London, UK

8. Modelling and Economics Unit, Centre for Infectious Disease Surveillance and Control, Public Health England, London, UK

9. Department of Infectious Disease Epidemiology, London School of Hygiene & Tropical Medicine, London, UK

10. St Mary’s Hospital, Imperial College Healthcare Trust, London, UK

Abstract

Background Interferon gamma release assays (IGRAs) are blood tests recommended for the diagnosis of tuberculosis (TB) infection. There is currently uncertainty about the role and clinical utility of IGRAs in the diagnostic workup of suspected active TB in routine NHS clinical practice. Objectives To compare the diagnostic accuracy and cost-effectiveness of T-SPOT.TB ® (Oxford Immunotec, Abingdon, UK) and QuantiFERON® TB GOLD In-Tube (Cellestis, Carnegie, VIC, Australia) for diagnosis of suspected active TB and to estimate the diagnostic accuracy of second-generation IGRAs. Design Prospective within-patient comparative diagnostic accuracy study. Setting Secondary care. Participants Adults (aged ≥ 16 years) presenting as inpatients or outpatients at 12 NHS hospital trusts in London, Slough, Oxford, Leicester and Birmingham with suspected active TB. Interventions The index tests [T-SPOT.TB and QuantiFERON GOLD In-Tube (QFT-GIT)] and new enzyme-linked immunospot assays utilising novel Mycobacterium tuberculosis antigens (Rv3615c, Rv2654, Rv3879c and Rv3873) were verified against a composite reference standard applied by a panel of clinical experts blinded to IGRA results. Main outcome measures Sensitivity, specificity, predictive values and likelihood ratios were calculated to determine diagnostic accuracy. A decision tree model was developed to calculate the incremental costs and incremental health utilities [quality-adjusted life-years (QALYs)] of changing from current practice to using an IGRA as an initial rule-out test. Results A total of 363 patients had active TB (culture-confirmed and highly probable TB cases), 439 had no active TB and 43 had an indeterminate final diagnosis. Comparing T-SPOT.TB and QFT-GIT, the sensitivities [95% confidence interval (CI)] were 82.3% (95% CI 77.7% to 85.9%) and 67.3% (95% CI 62.1% to 72.2%), respectively, whereas specificities were 82.6% (95% CI 78.6% to 86.1%) and 80.4% (95% CI 76.1% to 84.1%), respectively. T-SPOT.TB was more sensitive than QFT-GIT (relative sensitivity 1.22, 95% CI 1.14 to 1.31; p < 0.001), but the specificities were similar (relative specificity 1.02, 95% CI 0.97 to 1.08; p = 0.3). For both IGRAs the sensitivity was lower and the specificity was higher for human immunodeficiency virus (HIV)-positive than for HIV-negative patients. The most promising novel antigen was Rv3615c. The added value of Rv3615c to T-SPOT.TB was a 9% (95% CI 5% to 12%) relative increase in sensitivity at the expense of specificity, which had a relative decrease of 7% (95% CI 4% to 10%). The use of current IGRA tests for ruling out active TB is unlikely to be considered cost-effective if a QALY was valued at £20,000 or £30,000. For T-SPOT.TB, the probability of being cost-effective for a willingness to pay of £20,000/QALY was 26% and 21%, when patients with indeterminate test results were excluded or included, respectively. In comparison, the QFT-GIT probabilities were 8% and 6%. Although the use of IGRAs is cost saving, the health detriment is large owing to delay in diagnosing active TB, leading to prolonged illness. There was substantial between-patient variation in the tests used in the diagnostic pathway. Limitations The recruitment target for the HIV co-infected population was not achieved. Conclusions Although T-SPOT.TB was more sensitive than QFT-GIT for the diagnosis of active TB, the tests are insufficiently sensitive for ruling out active TB in routine clinical practice in the UK. Novel assays offer some promise. Future work The novel assays require evaluation in distinct clinical settings and in immunosuppressed patient groups. Funding This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and the NIHR Health Protection Research Unit in Respiratory Infections, Imperial College London, London, UK.

Funder

Health Technology Assessment programme

National Institute for Health Research Health Protection Research Unit in Respiratory Infections, Imperial College London, London, UK

Publisher

National Institute for Health Research

Subject

Health Policy

Cited by 17 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献