Non-invasive testing for early detection of neovascular macular degeneration in unaffected second eyes of older adults: EDNA diagnostic accuracy study

Author:

Banister Katie1ORCID,Cook Jonathan A2ORCID,Scotland Graham13ORCID,Azuara-Blanco Augusto4ORCID,Goulão Beatriz1ORCID,Heimann Heinrich5ORCID,Hernández Rodolfo3ORCID,Hogg Ruth4ORCID,Kennedy Charlotte3ORCID,Sivaprasad Sobha6ORCID,Ramsay Craig1ORCID,Chakravarthy Usha4ORCID

Affiliation:

1. Health Services Research Unit, University of Aberdeen, Aberdeen, UK

2. Centre for Statistics in Medicine, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford, UK

3. Health Economics Research Unit, University of Aberdeen, Aberdeen, UK

4. Centre for Public Health, Queen’s University Belfast, Belfast, UK

5. Liverpool University Hospitals NHS Foundation Trust, Liverpool, UK

6. National Institute for Health Research Moorfields Biomedical Research Centre, Moorfields Eye Hospital NHS Foundation Trust, London, UK

Abstract

Background Neovascular age-related macular degeneration is a leading cause of sight loss, and early detection and treatment is important. For patients with neovascular age-related macular degeneration in one eye, it is usual practice to monitor the unaffected eye. The test used to diagnose neovascular age-related macular degeneration, fundus fluorescein angiography, is an invasive test. Non-invasive tests are available, but their diagnostic accuracy is unclear. Objectives The primary objective was to determine the diagnostic monitoring performance of tests for neovascular age-related macular degeneration in the second eye of patients with unilateral neovascular age-related macular degeneration. The secondary objectives were the cost-effectiveness of tests and to identify predictive factors of developing neovascular age-related macular degeneration. Design This was a multicentre, prospective, cohort, comparative diagnostic accuracy study in a monitoring setting for up to 3 years. A Cox regression risk prediction model and a Markov microsimulation model comparing cost-effectiveness of the index tests over 25 years were used. Setting This took place in hospital eye services. Participants Participants were adults (aged 50–95 years) with newly diagnosed (within the previous 6 weeks) neovascular age-related macular degeneration in one eye and an unaffected second (study) eye who were attending for treatment injections in the first eye and who had a study eye baseline visual acuity of ≥ 68 Early Treatment Diabetic Retinopathy Study letters. Interventions The index tests were Amsler chart (completed by participants), fundus clinical examination, optical coherence tomography, self-reported vision assessment (completed by participants) and visual acuity. The reference standard was fundus fluorescein angiography. Main outcome measures The main outcome measures were sensitivity and specificity; the performance of the risk predictor model; and costs and quality-adjusted life-years. Results In total, 552 out of 578 patients who consented from 24 NHS hospitals (n = 16 ineligible; n = 10 withdrew consent) took part. The mean age of the patients was 77.4 years (standard deviation 7.7 years) and 57.2% were female. For the primary analysis, 464 patients underwent follow-up fundus fluorescein angiography and 120 developed neovascular age-related macular degeneration on fundus fluorescein angiography. The diagnostic accuracy [sensitivity (%) (95% confidence interval); specificity (%) (95% confidence interval)] was as follows: optical coherence tomography 91.7 (85.2 to 95.6); 87.8 (83.8 to 90.9)], fundus clinical examination [53.8 (44.8 to 62.5); 97.6 (95.3 to 98.9)], Amsler [33.7 (25.1 to 43.5); 81.4 (76.4 to 85.5)], visual acuity [30.0 (22.5 to 38.7); 66.3 (61.0 to 71.1)] and self-reported vision [4.2 (1.6 to 9.8); 97.0 (94.6 to 98.5)]. Optical coherence tomography had the highest sensitivity across all secondary analyses. The final prediction model for neovascular age-related macular degeneration in the non-affected eye included smoking status, family history of neovascular age-related macular degeneration, the presence of nodular drusen with or without reticular pseudodrusen, and the presence of pigmentary abnormalities [c-statistic 0.66 (95% confidence interval 0.62 to 0.71)]. Optical coherence tomography monitoring generated the greatest quality-adjusted life-years gained per patient (optical coherence tomography, 5.830; fundus clinical examination, 5.787; Amsler chart, 5.736, self-reported vision, 5.630; and visual acuity, 5.600) for the lowest health-care and social care costs (optical coherence tomography, £19,406; fundus clinical examination, £19,649; Amsler chart, £19,751; self-reported vision, £20,198; and visual acuity, £20,444) over the lifetime of the simulated cohort. Optical coherence tomography dominated the other tests or had an incremental cost-effectiveness ratio below the accepted cost-effectiveness thresholds (£20,000) across the scenarios explored. Limitations The diagnostic performance may be different in an unselected population without any history of neovascular age-related macular degeneration; the prediction model did not include genetic profile data, which might have improved the discriminatory performance. Conclusions Optical coherence tomography was the most accurate in diagnosing conversion to neovascular age-related macular degeneration in the fellow eye of patients with unilateral neovascular age-related macular degeneration. Economic modelling suggests that optical coherence tomography monitoring is cost-effective and leads to earlier diagnosis of and treatment for neovascular age-related macular degeneration in the second eye of patients being treated for neovascular age-related macular degeneration in their first eye. Future work Future works should investigate the role of home monitoring, improved risk prediction models and impact on long-term visual outcomes. Study registration This study was registered as ISRCTN48855678. Funding This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 26, No. 8. See the NIHR Journals Library website for further project information.

Funder

Health Technology Assessment programme

Publisher

National Institute for Health Research

Subject

Health Policy

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3