AbstractBackground: Clinicians in outpatient clinics and emergency departments desire an accurate quantitative D-dimer assay. The study objective was to evaluate the diagnostic performance characteristics of the latex turbidimetric D-dimer test in the diagnosis of pulmonary embolism (PE) in the emergency department population.Methods: We conducted a search of MEDLINE, EMBASE, and bibliographies of previous systematic reviews with no language restriction. Experts in the field of PE research were contacted to identify unpublished studies. Prospective investigations involving predominately outpatient populations with suspected PE that used a turbidimetric D-dimer test were included. Two authors extracted data independently and assessed study quality based on the composition of the patient spectrum and the reference standard used. Consensus was reached by conference. The analysis was based on a summary ROC curve and combining sensitivity and specificity independently across studies using a random-effects model.Results: The search yielded 264 publications and 2 unpublished studies. Nine studies met the inclusion criteria and provided a sample of 1901 individuals. Eight of the nine studies were homogeneous in terms of both sensitivity and specificity. One study had similar sensitivity but higher specificity. Combining the studies yielded an overall sensitivity of 0.93 (95% confidence interval, 0.89–0.96) and an overall specificity of 0.51 (95% confidence interval, 0.42–0.59).Conclusions: The turbidimetric D-dimer test is sensitive but nonspecific for the detection of PE in the emergency department setting. D-Dimer tests using latex turbidimetric methods appear to have test characteristics comparable to those for ELISA methods.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 67 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Cardiothoracale beeldvorming;De dokter en het beeld;2023

2. Development of aptamer‐based ELISA method for d ‐dimer detection;Biotechnology and Applied Biochemistry;2022-04-25

3. D-dimer level as a predictor of adverse outcomes in patients with ischemic stroke;Yakut Medical Journal;2021

4. High-Risk Chief Complaints I;Emergency Medicine Clinics of North America;2020-05

5. Evaluation of Plasma D-Dimer Concentration Among Normal and Complicated Pregnancies, Saudi Arabia;International Journal of Women's Health and Reproduction Sciences;2018-11-02