Whole-Blood Thrombin Generation Monitored with a Calibrated Automated Thrombogram-Based Assay

Author:

Ninivaggi Marisa1,Apitz-Castro Rafael1,Dargaud Yesim2,de Laat Bas1,Hemker H Coenraad1,Lindhout Theo1

Affiliation:

1. Synapse BV, CARIM, Maastricht University Medical Center, Maastricht, the Netherlands

2. Unite d'Hemostase Clinique, Hopital Edouard Herriot, Lyon, France

Abstract

Abstract BACKGROUND The calibrated automated thrombogram (CAT) assay in plasma is a versatile tool to investigate patients with hypo- or hypercoagulable phenotypes. The objective was to make this method applicable for whole blood measurements. METHODS Thin-layer technology and the use of a rhodamine 110–based thrombin substrate appear to be essential for a reliable thrombin generation (TG) assay in whole blood. Using this knowledge we developed a whole blood CAT-based assay. RESULTS We demonstrated that the whole blood CAT-based assay is a sensitive and rapid screening test to assess function of the hemostatic system under more nearly physiological conditions than the TG assay in plasma. Under conditions of low tissue factor concentration (0.5 pmol/L) and 50% diluted blood, the intraassay CV of the thrombogram parameters, endogenous thrombin potential and thrombin peak height, were 6.7% and 6.5%, respectively. The respective interassay CVs were 12% and 11%. The mean interindividual variation (SD) of 40 healthy volunteers was 633 (146) nmol · min/L for the endogenous thrombin potential and 128 (23) nmol/L for the thrombin peak. Surprisingly, erythrocytes contributed more than platelets to the procoagulant blood cell membranes necessary for optimal TG. Statistically significant (P < 0.001) and potentially clinically significant correlations were observed between circulating factor-VIII concentrations in blood of hemophilia A patients and endogenous thrombin potential (r = 0.62) and thrombin peak height (r = 0.58). CONCLUSIONS We have developed a reliable method to measure TG in whole blood. The assay can be performed with a drop of blood and may provide a useful measurement of TG under more physiological conditions than plasma.

Funder

Center for Translational Molecular Medicine

Netherlands Heart Foundation

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

Cited by 95 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3