Evaluation of Tumor Measurements in Oncology: Use of Film-Based and Electronic Techniques

Author:

Schwartz Lawrence H.1,Ginsberg Michelle S.1,DeCorato Douglas1,Rothenberg Lawrence N.1,Einstein Steven1,Kijewski Peter1,Panicek David M.1

Affiliation:

1. From the Departments of Radiology and Medical PhysicsMemorial Sloan-Kettering Cancer Center, and Weill Medical College at Cornell University, New York, NY, and Bioimaging Technologies, West Trenton, NJ.

Abstract

PURPOSE: To evaluate the variability in bidimensional computed tomography (CT) measurements obtained of actual tumors and of tumor phantoms by use of three measurement techniques: hand-held calipers on film, electronic calipers on a workstation, and an autocontour technique on a workstation. MATERIALS AND METHODS: Three radiologists measured 45 actual tumors (in the lung, liver, and lymph nodes) on CT images, using each of the three techniques. Bidimensional measurements were recorded, and their cross-products calculated. The coefficient of variation was calculated to assess interobserver variability. CT images of 48 phantoms were measured by three radiologists with each of the techniques. In addition to the coefficient of variation, the differences between the cross-product measurements of tumor phantoms themselves and the measurements obtained with each of the techniques were calculated. RESULTS: The differences between the coefficients of variation were statistically significantly different for the autocontour technique, compared with the other techniques, both for actual tumors and for tumor phantoms. There was no statistically significant difference in the coefficient of variation between measurements obtained with hand-held calipers and electronic calipers. The cross-products for tumor phantoms were 12% less than the actual cross-product when calipers on film were used, 11% less using electronic calipers, and 1% greater using the autocontour technique. CONCLUSION: Tumor size is obtained more accurately and consistently between readers using an automated autocontour technique than between those using hand-held or electronic calipers. This finding has substantial implications for monitoring tumor therapy in an individual patient, as well as for evaluating the effectiveness of new therapies under development.

Publisher

American Society of Clinical Oncology (ASCO)

Subject

Cancer Research,Oncology

Cited by 91 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3