Multicenter Trial of [18F]fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Staging of Head and Neck Cancer and Negative Predictive Value and Surgical Impact in the N0 Neck: Results From ACRIN 6685

Author:

Lowe Val J.1,Duan Fenghai2,Subramaniam Rathan M.3,Sicks JoRean D.2,Romanoff Justin2,Bartel Twyla4,Yu Jian Q. (Michael)5,Nussenbaum Brian6,Richmon Jeremy7,Arnold Charles D.8,Cognetti David9,Stack Brendan C.10

Affiliation:

1. Mayo Clinic, Rochester, MN

2. Brown University School of Public Health, Providence, RI

3. University of Texas Southwestern Medical Center, Dallas, TX

4. Global Advanced Imaging, Little Rock, AR

5. Fox Chase Cancer Center, Philadelphia, PA

6. Washington University School of Medicine, St. Louis, MO

7. Massachusetts Eye and Ear Hospital, Boston, MA

8. University of Oklahoma, Oklahoma City, OK

9. Sidney Kimmel Cancer Center at Thomas Jefferson University, Philadelphia, PA

10. University of Arkansas for Medical Sciences, Little Rock, AR

Abstract

PURPOSE The objective of this study was to determine the negative predictive value (NPV) of positron emission tomography (PET)/computed tomography (CT) for the clinically N0 neck on the basis of neck dissection. METHODS Participants with newly diagnosed, first-time, head and neck squamous cell carcinoma (HNSCC) and at least one clinically N0 neck side for which dissection was planned were included. A total of 287 participants were prospectively enrolled from 23 American College of Radiology Imaging Network-qualified institutions. PET/CT was compared with findings at neck dissection. RESULTS PET/CT scans and pathology findings were available for 270 N0 neck sides from 212 participants. For visual assessment, the NPV specific to the clinical-N0 sides was 0.868 (95% CI, 0.803 to 0.925). For dichotomized maximum standardized uptake value, the NPVs specific to the nodal basins were 0.940 (95% CI, 0.928 to 0.952) and 0.937 (95% CI, 0.925 to 0.949) at prespecified cutoffs of 2.5 and 3.5, respectively. The optimal cutoff maximum standardized uptake value was determined to be 1.8, with an NPV of 0.942 (95% CI, 0.930 to 0.953). The PET/CT-informed surgical treatment plan was changed in 51 of 237 participants (22%) compared with the PET/CT-blinded surgical plan. In 34 participants (14%), this led to planned dissection of additional nodal levels. In 12 participants (5%), this led to fewer planned dissected nodal levels. Negative PET/CT scans in N0 necks was true negative in 87% and false negative in 13%. CONCLUSION [18F]fluorodeoxyglucose-PET/CT has high NPV for the N0 neck in T2 to T4 HNSCC. The surgical treatment plans on the basis of PET/CT findings may be changed in approximately 22% of this group. These findings suggest that [18F]fluorodeoxyglucose-PET/CT may assist the clinician in deciding on the best therapy for the clinically N0 neck in HNSCC. Well-designed clinical trials should be performed to test the outcome of omitting neck dissection by using PET/CT.

Publisher

American Society of Clinical Oncology (ASCO)

Subject

Cancer Research,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3