Author:
Nakamura Satoshi,Takemori Mihiro,Nakaichi Tetsu,Shuto Yasunori,Kashihara Tairo,Iijima Kotaro,Chiba Takahito,Nakayama Hiroki,Urago Yuka,Nishina Shuka,Kobayashi Yuta,Kishida Hironori,Imamichi Shoji,Takahashi Kana,Masutani Mitsuko,Okamoto Hiroyuki,Nishio Teiji,Itami Jun,Igaki Hiroshi
Abstract
AbstractAccelerator-based boron neutron capture therapy (BNCT) systems employing a solid-state lithium target indicated the reduction of neutron flux over the lifetime of a target, and its reduction could represent the neutron flux model. This study proposes a novel compensatory approach for delivering the required neutron fluence and validates its clinical applicability. The proposed approach relies on the neutron flux model and the cumulative sum of real-time measurements of proton charges. The accuracy of delivering the required neutron fluence for BNCT using the proposed approach was examined in five Li targets. With the proposed approach, the required neutron fluence could be delivered within 3.0%, and within 1.0% in most cases. However, those without using the proposed approach exceeded 3.0% in some cases. The proposed approach can consider the neutron flux reduction adequately and decrease the effect of uncertainty in neutron measurements. Therefore, the proposed approach can improve the accuracy of delivering the required fluence for BNCT even if a neutron flux reduction is expected during treatment and over the lifetime of the Li target. Additionally, by adequately revising the approach, it may apply to other type of BNCT systems employing a Li target, furthering research in this direction.
Funder
Japan Society for the Promotion of Science
Japan Agency for Medical Research and Development
Publisher
Springer Science and Business Media LLC
Reference29 articles.
1. Aihara, T. et al. BNCT for advanced or recurrent head and neck cancer. Appl. Radiat. Isot. 88, 12–15 (2014).
2. Farr, L. E. et al. Neutron capture therapy with boron in the treatment of glioblastoma multiforme. Am. J. Roentgenol. Radium. Ther. Nucl. Med. 71(2), 279–293 (1954).
3. Finkel, G. C., Poletti, C. E., Fairchild, R. G., Slatkin, D. N. & Sweet, W. H. Distribution of 10B after infusion of Na210B12H11SH into a patient with malignant astrocytoma: implications for boron neutron capture therapy. Neurosurgery 24(1), 6–11 (1989).
4. Futamura, G. et al. A case of radiation-induced osteosarcoma treated effectively by boron neutron capture therapy. Radiat. Oncol. 9, 237 (2014).
5. Hatanaka, H. & Sano, K. A revised boron-neutron capture therapy for malignant brain tumours. I. Experience on terminally ill patients after Co-60 radiotherapy. Z. Neurol. 204(4), 309–332 (1973).
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. The Development of Neutron Flux Monitoring System Using ESP32 Module in Kartini Research Reactor;2024 International Seminar on Intelligent Technology and Its Applications (ISITIA);2024-07-10