Author:
Shimada Yoshihisa,Kudo Yujin,Maehara Sachio,Fukuta Kentaro,Masuno Ryuhei,Park Jinho,Ikeda Norihiko
Abstract
AbstractWe aimed to investigate the value of computed tomography (CT)-based radiomics with artificial intelligence (AI) in predicting pathological lymph node metastasis (pN) in patients with clinical stage 0–IA non-small cell lung cancer (c-stage 0–IA NSCLC). This study enrolled 720 patients who underwent complete surgical resection for c-stage 0–IA NSCLC, and were assigned to the derivation and validation cohorts. Using the AI software Beta Version (Fujifilm Corporation, Japan), 39 AI imaging factors, including 17 factors from the AI ground-glass nodule analysis and 22 radiomics features from nodule characterization analysis, were extracted to identify factors associated with pN. Multivariate analysis showed that clinical stage IA3 (p = 0.028), solid-part size (p < 0.001), and average solid CT value (p = 0.033) were independently associated with pN. The receiver operating characteristic analysis showed that the area under the curve and optimal cut-off values of the average solid CT value relevant to pN were 0.761 and -103 Hounsfield units, and the threshold provided sensitivity, specificity, and negative predictive values of 69%, 65%, and 94% in the entire cohort, respectively. Measuring the average solid-CT value of tumors for pN may have broad applications such as guiding individualized surgical approaches and postoperative treatment.
Publisher
Springer Science and Business Media LLC
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献