Feasibility study of cryoballoon ablation for atrial fibrillation with KODEX-EPD: a single center experience

Author:

Wubulikasimu Subinuer,Wang Liang,Yang Suxia,Sang Wanyue,Han Yafan,Wang Lu,Wang Feifei,Zhou Xianhui,Zhang Jianghua,Xing Qiang,Tuerhong Zukela,Xiaokereti Jiasuoer,Guo Yankai,Tang Baopeng,Li Yaodong

Abstract

AbstractTo evaluate the feasibility of cryoballoon (CB) ablation of atrial fibrillation (AF) under the guidance of a new three-dimensional (3D) mapping system KODEX-EPD. 40 patients scheduled for CB ablation of AF in the first affiliated Hospital of Xinjiang Medical University from August 2021 to July 2022 were randomly divided into two groups: KODEX-EPD 3D mapping system guidance group (KODEX group, n = 20) and conventional two-dimensional perspective group (standard group, n = 20). The ablation time, operation time, fluoroscopy time, fluoroscopy dose, contrast agent dosage and follow-up data were compared between the two groups. Besides, the feasibility and accuracy of the dielectric sensing system in evaluating pulmonary vein (PV) occlusion in patients with AF during CB ablation were verified. All pulmonary veins were being isolated. The ablation time (36.40 ± 6.72 min vs 35.15 ± 6.29 min, P > 0.05) and the operation time (64.20 ± 11.82 min vs 66.00 ± 13.18 min, P > 0.05) were not statistically different in the two groups. The standard group has longer fluoroscopy time, dose and contrast medium dosage. There were significant differences in fluoroscopy time (532.30 ± 72.83 s vs 676.25 ± 269.33 s, P < 0.05), fluoroscopy dose (110.00 ± 28.64 mGy vs 144.68 ± 66.66 mGy, P < 0.05), and contrast medium dosage (71.90 ± 5.97 ml vs 76.05 ± 5.93 ml, P < 0.05) between the two groups. The learning curves of the first 5 patients and the last 15 patients in the KODEX group were compared. There was no statistical difference in the ablation time (36.80 ± 8.56 min vs 36.27 ± 6.34 min, P > 0.05) or the operation time (69.00 ± 5.00 min vs 62.60 ± 13.10 min, P > 0.05); however, compared to the first 5 patients, fluoroscopy time (587.40 ± 38.34 s vs 513.93 ± 73.02 s, P < 0.05), fluoroscopy dose (147.85 ± 35.19 mGy vs 97.39 ± 8.80 mGy, P < 0.05) and contrast medium dosage (79.60 ± 1.14 ml vs 69.33 ± 4.45 ml, P < 0.05) were significantly decreased. Using pulmonary venography as the gold standard, the sensitivity, specificity of the completely occlusion in KODEX group was 93.6% (95% CI 85–97.6%) and 69.6% (95% CI 54–81.8%); and the sensitivity, specificity of the small leak in KODEX group was 93.1% (95% CI 82.4–97.8%) and 82.0% (95% CI 65.9–91.9%). During an average follow-up of (9.90 ± 1.06) months, there was no statistical difference in arrhythmia recurrence and antiarrhythmic drugs taking after CB ablation between the two groups (P > 0.05). Using the KODEX-EPD system, the CB ablation procedure can correctly evaluate the PV occlusion, and significantly reduce fluoroscopy exposure and contrast medium without significantly increasing the operation time.

Funder

Science Fund for Distinguished Young Scholars of Xinjiang Autonomous Region

Key R&D Program of Xinjiang Uygur Autonomous Region

National Natural Science Foundation of China

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3