Feasibility and safety of fine positioning needle-mediated breathing control in CT-guided percutaneous puncture of small lung/liver nodules adjacent to diaphragm

Author:

Wu Qingde,Cao Bihui,Zheng Yujin,Liang Baoxia,Liu Manting,Wang Lu,Zhang Jinling,Meng Liyan,Luo Shaoyong,He Xuxia,Zhang Zhenfeng

Abstract

AbstractTo assess the efficacy, safety, and feasibility of a separate inserted positioning fine needle-mediated breathing-control technique applied to computed tomography (CT)-guided percutaneous puncture for biopsy or microwave ablation (MWA) of small lung/liver nodules near diaphragm. Total 46 patients with pulmonary/liver small nodules (≤ 3 cm in size) near diaphragm(nodule within 1 cm distance to the diaphragm)were undergone percutaneous biopsy ( n = 15) or MWA (n = 31) under the guidance of CT, and a separate positioning fine needle-mediated breathing-control technique was applied for the precise punctures. CT plain scan was performed to monitor the complications after the procedure. The patient baseline data, operation details, successful rate, major complications as well as radiation dose during the procedure were recorded and analyzed. With the assistance of a fine positioning needle insertion for controlling the breathing, the puncture success rate for biopsy or MWA reached 91.30% (42/46). For biopsy, the mean nodule diameter, nodule distance to the diaphragm, puncture time and radiation dose during CT scan were 2.27 cm ± 0.74, 0.61 cm ± 0.24, 18.67 min ± 6.23, 28.84 mSv ± 6.99, respectively; For MWA, the mean nodule diameter, nodule distance to the diaphragm, puncture time and CT radiation dose were 2.35 cm ± 0.64, 0.69 cm ± 0.23, 38.71 min ± 13.65, 33.02 mSv ± 8.77, respectively. Totally, there were three and four cases found minimal puncture-related hemoptysis and pneumothorax needed no additional treatments, respectively. We recently developed and verified a feasible, safe and highly effective puncture technique with reasonable radiation dose for CT-guided biopsy or MWA for small nodules abutting diaphragm, therefore worthy of extensive application to similar clinical situations.

Funder

Guangzhou Science and Technology Program

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3