Author:
Minagawa Hiroki,Yoshimura Shinji,Terasaka Kenichiro,Aramaki Mitsutoshi
Abstract
AbstractTunable diode laser absorption spectroscopy (TDLAS) is a valuable method for measuring particle flow velocities in plasma. However, conventional TDLAS using a plane-wave beam is sensitive only to the laser propagation direction. This limitation is particularly unfavorable for the observation of the particle transportation perpendicularly incident on the material in the plasma–material interaction. In this paper, we show for the first time that flow measurements perpendicular to the beam direction are possible by replacing the probe beam with an optical vortex beam. Because an optical vortex has a helical wavefront, particles moving in its field experience an azimuthal Doppler shift in addition to the translational Doppler shift. Assuming a uniform gas flow across the optical vortex, the azimuthal Doppler shift of the absorption spectrum observed in the beam cross-section varies sinusoidally in the azimuthal direction. The transverse flow velocity is derived from the amplitude of this sinusoidal variation. At transverse velocities above 70 m/s, the measurement errors are found to be less than 15%, with a mean absolute percentage error of less than 8%.
Funder
MEXT | Japan Society for the Promotion of Science
MEXT | NINS | National Institute for Fusion Science
Publisher
Springer Science and Business Media LLC
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献