Author:
Gareb Barzi,van Munster Valerie D. M.,Dijkstra Pieter U.,Bos Ruud R. M.,Vissink Arjan,van Bakelen Nico B.,van Minnen Baucke
Abstract
AbstractApplying the right torque to osteosynthesis screws is important for undisturbed bone healing. This study aimed to compare test–retest and intra-individual reliabilities of the torque applied to 1.5 mm and 2.0 mm osteosynthesis screws by residents and oral and maxillofacial surgeons (OMF-surgeons), to define the reference torque intervals, and to compare reference torque interval compliances. Five experienced OMF-surgeons and 20 residents, 5 of each 4 residency years, were included. Each participant inserted six 1.5 × 4 mm and six 2.0 × 6 mm screws into a preclinical model at two test moments 2 weeks apart (T1 and T2). Participants were blinded for the applied torque. Descriptive statistics, reference intervals, and intra-class correlation coefficients (ICC) were calculated. The OMF-surgeons complied more to the reference intervals (1.5 mm screws: 95% and 2.0 mm screws: 100%) than the residents (82% and 90%, respectively; P = 0.009 and P = 0.007) with the ICCs ranging between 0.85–0.95 and 0.45–0.97, respectively. The residents’ accuracy and reliability were inadequate regarding the 1.5 mm screws but both measures improved at T2 for both screw types compared to T1, indicating a learning effect. Training residents and/or verifying the applied torque by experienced OMF-surgeons remains necessary to achieve high accuracy and reliability, particularly for 1.5 mm screws.
Funder
BOOA research grant from the Dutch Society of Oral and Maxillofacial Surgery (NVMKA).
Strasbourg Osteosynthesis Research Group (SORG) research grant
Publisher
Springer Science and Business Media LLC
Reference27 articles.
1. Fletcher, J. W. A. et al. Surgical performance when inserting non-locking screws: A systematic review. EFORT Open Rev. 5, 26–36 (2020).
2. Gareb, B. et al. Biodegradable versus titanium osteosyntheses in maxillofacial traumatology: a systematic review with meta-analysis and trial sequential analysis. Int. J. Oral Maxillofac. Surg. 49, 914–931 (2020).
3. Gareb, B. et al. Efficacy and morbidity of biodegradable versus titanium osteosyntheses in orthognathic surgery: A systematic review with meta-analysis and trial sequential analysis. Eur. J. Oral Sci. 29, e12800 (2021).
4. Boudreau, B. et al. Effect of screw insertion torque on mechanical properties of four locking systems. Vet Surg. 42, 535–543 (2013).
5. West, G. H. et al. Treatment outcomes with the use of maxillomandibular fixation screws in the management of mandible fractures. J. Oral Maxillofac. Surg. 72, 112–120 (2014).
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献