Gasparin Aléxia Thamara,Araujo Claudiane Isabel Franco,Schmitt Patricia,Cardoso Mônica Ribas,Perussolo Maiara Carolina,de Jesus Thainá Caroline Schuartz,Santiago Erika Bergamo,Silva Ivan Lucas Reis,de Sousa Ricardo Gurgel,Teng Flavia Zhu,Severo Evair Borges,Ribeiro Victor Henrique Alves,Cardoso Milena Andreuzo,Silva Fernanda D’Amico,de Araujo Perazzoli Carolina Rodrigues,de Holanda Farias João Samuel,de Almeida Bernardo Montesanti Machado,Rogal Júnior Sergio Renato,Figueredo Marcus Vinícius Mazega
Abstract
AbstractThe complete blood count (CBC) is one of the most requested tests by physicians. CBC tests, most realized in conventional hematological analyzers, are restricted to centralized laboratories due to frequent maintenance, large devices, and expensive costs required. On the other hand, most handheld CBC devices commercially available show high prices and are not liable to calibration or control procedures, which results in poor quality compared to standard hematology instruments. The Hilab system is a small-handed hematological platform that uses microscopy and chromatography techniques for blood cells and hematimetric parameters analysis through artificial intelligence, machine learning, and deep learning techniques. For clinical evaluation of the handheld CBC device, 450 blood samples were analyzed. The samples encompassed normal (82%) and pathological conditions (18%), such as thalassemias (2.2%), anemias (6.6%), and infections (9.2%). For all analytes, accuracy, precision, method comparison, and flagging capabilities of the Hilab System, were compared with the Sysmex XE-2100 (Sysmex, Japan) results. The sample source (venous and capillary) influences were also evaluated. Pearson correlation, Student t test, bias, and the Bland–Altman plot of each blood count analyte were calculated and shown. The significance level was set at p ≤ 0.05. For clinical evaluation, Hilab System and the Sysmex XE-2100 showed a strong correlation (r ≥ 0.9) for most evaluated parameters. In the precision study, analytes showed CV inside the limits established according to European Federation of Clinical Chemistry and Laboratory Medicine guidelines. The flagging capabilities of the Hilab system, compared to the manual microscopy technique, presented high sensibility, specificity, and accuracy. Venous and capillary samples (p > 0.05) do not differ statistically. Considering the need for point-of-care CBCs, the study indicated that the Hilab system provides fast, accurate, low cost, and robust analysis for reliable clinical use.
Publisher
Springer Science and Business Media LLC
Reference13 articles.
1. Agarwal, A. et al. Differentiation of leukemic blasts is not completely blocked in acute myeloid leukemia. Proc. Natl. Acad. Sci. U.S.A. 116(49), 24593–24599 (2019).
2. World Health Organization. The Selection and Use of Essential In Vitro Diagnostics (World Health Organization, 2020).
3. Celkan, T. T. What does a hemogram say to us?. Turk. Pediatr. Ars. 55(2), 103–116 (2020).
4. Bachar, N. et al. An artificial intelligence-assisted diagnostic platform for rapid near-patient hematology. Am. J. Hematol. 96(10), 1264–1274 (2021).
5. Osei-Bimpong, A., Jury, C., Mclean, R. & Lewis, S. M. Point-of-care method for total white cell count: An evaluation of the HemoCue WBC device. Int. J. Lab. Hematol. 31(6), 657–664 (2009).