Safety and efficacy of fluoroscopy-guided urethral catheterization in case of failed blind or cystoscopy-assisted urethral catheterization

Author:

Kim Sang Woo,Nam In Chul,Kim Doo Ri,Lee Jeong Sub,Kim Jeong Jae,Kim Bong Su,Choi Guk Myung,Park Sung Eun

Abstract

AbstractThis retrospective study evaluated the safety and efficacy of fluoroscopy-guided urethral catheterization in patients who failed blind or cystoscopy-assisted urethral catheterization. We utilized our institutional database between January 2011 and March 2023, and patients with failed blind or cystoscopy-assisted urethral catheterization and subsequent fluoroscopy-guided urethral catheterization were included. A 5-Fr catheter was inserted into the urethral orifice, and the retrograde urethrography (RGU) was acquired. Subsequently, the operator attempted to pass a hydrophilic guidewire to the urethra. If the guidewire and guiding catheter could be successfully passed into the bladder, but the urethral catheter failed pass due to urethral stricture, the operator determined either attempted again with a reduced catheter diameter or performed balloon dilation according to their preference. Finally, an appropriately sized urethral catheter was selected, and an endhole was created using an 18-gauge needle. The catheter was then inserted over the wire to position the tip in the bladder lumen and ballooned to secure it. We reviewed patients’ medical histories, the presence of hematuria, and RGU to determine urethral abnormalities. Procedure-related data were assessed. Study enrolled a total of 179 fluoroscopy-guided urethral catheterizations from 149 patients (all males; mean age, 73.3 ± 13.3 years). A total of 225 urethral strictures were confirmed in 141 patients, while eight patients had no strictures. Urethral rupture was confirmed in 62 patients, and hematuria occurred in 34 patients after blind or cystoscopy-assisted urethral catheterization failed. Technical and clinical success rates were 100%, and procedure-related complications were observed in four patients (2.2%). The mean time from request to urethral catheter insertion was 129.7 ± 127.8 min. The mean total fluoroscopy time was 3.5 ± 2.5 min and the mean total DAP was 25.4 ± 25.1 Gy cm2. Balloon dilation was performed in 77 patients. Total procedure time was 9.2 ± 7.6 min, and the mean procedure time without balloon dilation was 7.1 ± 5.7 min. Fluoroscopy-guided urethral catheterization is a safe and efficient alternative in patients where blind or cystoscopy-assisted urethral catheterization has failed or when cystoscopy-urethral catheterization cannot be performed.

Funder

Jeju National University Hospital

Publisher

Springer Science and Business Media LLC

Reference29 articles.

1. Saint, S., Lipsky, B. A. & Goold, S. D. Indwelling urinary catheters: A one-point restraint?. Ann. Intern. Med. 137, 125–127 (2002).

2. Levy, G. D. K. F. Genitourinary trauma. In Emergency Medicine-A Comprehensive Study Guide 6th edn (ed. Tintinalli, J. E.) 1622–1628 (McGraw-Hill, 2004).

3. Shackley, D. C. et al. Variation in the prevalence of urinary catheters: A profile of National Health Service patients in England. BMJ Open 7, e013842 (2017).

4. Stefanie, M. C. et al. A prospective multi-institutional evaluation of iatrogenic urethral catheterization injuries. J. Invest. Surg. 35, 1761–1766 (2002).

5. Leuck, A. M. et al. Complications of Foley catheters—Is infection the greatest risk?. J. Urol. 187, 1662–1666 (2012).