Abstract
AbstractAn experimental method has been developed for probing top-of-the-line corrosion (TLC) of pipeline steel based on the use of the wire beam electrode (WBE) in conjunction with local electrochemical measurements. Results show that the location of the droplet, the droplet retention time, the water condensation rate and the local TLC rate could be well determined through the macro-cell current mapping and local electrochemical measurements. The precipitation and the scaling tendency of the FeCO3 beneath the droplet were quantitatively estimated. The micro-cell corrosion was significantly influenced by the thickness of the condensed water film and the protectiveness of the FeCO3 layer. The discrepancy of the film formation inside and outside the droplets was the driving force of macro-cell corrosion. The in-situ measurement and visualization of the corrosion processes and kinetics using the modified WBE could be conveniently used to facilitate the understanding of the initiation and propagation of localized TLC.
Publisher
Springer Science and Business Media LLC
Subject
Materials Chemistry,Materials Science (miscellaneous),Chemistry (miscellaneous),Ceramics and Composites
Reference52 articles.
1. Gunaltun, Y. M., Supriyatman, D. & Achmad, J. Top-of-line corrosion in gas lines confirmed by condensation analysis. Oil Gas. J. 97, 64–72 (1999).
2. Zhang, Z. et al. A mechanistic model of top-of-the-line corrosion. Corrosion 63, 1051–1062 (2007).
3. Singer, M. et al. CO2 top-of-the-line corrosion in presence of acetic acid: a parametric study. Corrosion 69, 719–735 (2013).
4. Islam, M. M., Pojtanabuntoeng, T. & Gubner, R. Condensation corrosion of carbon steel at low to moderate surface temperature and iron carbonate precipitation kinetics. Corros. Sci. 111, 139–150 (2016).
5. Singer, M. Study of the localized nature of top of the line corrosion in sweet environment. Corrosion 73, 1030–1055 (2017).
Cited by
11 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献